1. Carefully roll the excess tubing and place it
behind the condenser.
2. Attach the bundle connections to the outside
condenser.
STEP 5 - outside
Carefully unroll to indoor
handler connection
Connect directly to
exterior condensor
Keep excess coiled
Radius
3. Using two crescent or adjustable wrenches,
screw the quick connect components together. Use
one to hold the valve and keep it from twisting and
the other to
tighten the fitting.
4. See manual for
tool and torque
requirements .
Improper
connection can
void warranty.
1. Remove the brass caps from the valves on the
exterior condenser unit.
2. Use an Allen Wrench to open the valve until it
stops turning. Be sure not to exert excessive force
on the valve. You may hear a soft hissing sound as
a slight amount of R-410a refrigerant exits the
condenser.
3. Apply soapy water or leak detection spray to the
Quick Connect
®
fittings. If you see bubbles, this
indicates there is a leak. Tighten the connection
accordingly until the bubbles are gone.