Outdoor Unit Dimensions (mm)
W x H x D
Mounting Dimensions
Distance A (mm) Distance B (mm)
685x430x260 (27 x17 x10.25 ) 460 (18.10 ) 276 (10.85 )
700x540x240 (27.5 x21.25 x9.45 ) 458 (18 ) 250 (9.85 )
780x540x250 (30.7 x21.25 x9.85 ) 549 (21.6 ) 276 (10.85 )
760x590x285 (29.9 x23.2 x11.2 ) 530 (20.85 ) 290 (11.4 )
845x700x320 (33.25 x27.5 x12.6 ) 560 (22 ) 335 (13.2 )
810x558x310 (31.9 x22 x12.2 ) 549 (21.6 ) 325 (12.8 )
900x860x315 (35.4 x33.85 x12.4 ) 590 (23.2 ) 333 (13.1 )
945x810x395 (37.2 x31.9 x15.55 ) 640 (25.2 ) 405 (15.95 )
on a concrete mounting platform, do the
following:
1. Mark the positions for four expansion bolts
based on dimensions in the Unit Mounting
Dimensions chart.
2. Pre-drill holes for expansion bolts.
3. Clean concrete dust away from holes.
4. Place a nut on the end of each expansion bolt.
5. Hammer expansion bolts into the pre-drilled
holes.
6. Remove the nuts from expansion bolts, and
place outdoor unit on bolts.
7. Put washer on each expansion bolt, then
replace the nuts.
8. Using a wrench, tighten each nut until snug.
WARNING
PROTECTION IS RECOMMENDED AT ALL
TIMES.
Step 3: Anchor outdoor unit
The outdoor unit can be anchored to the ground
or to a wall-mounted bracket.
UNIT MOUNTING DIMENSIONS
The following is a list of different outdoor unit
sizes and the distance between their mounting
feet. Prepare the installation base of the unit
according to the dimensions below.
W
A
B
D
Ai r Inlet
Ai r Outlet
Ai r Inlet
Fig. 4.5