Step 1: Selecting an Installation Location 
Before installing the outdoor unit, you must 
choose an appropriate location. Use the following
guidelines to help you select an appropriate 
location. 
Proper installation locations should meet 
following guidelines:
Meets all spatial requirements shown in
in the illustration above (Fig. 6.1) 
Good air circulation and ventilation
Firm and solid location that can support 
the unit and will not cause vibration
Noise from the unit will not disturb others 
Protected from prolonged periods of 
exposure to direct sunlight or rain
If installed in an area where snowfall is 
expected, take appropriate measures to 
prevent ice buildup and coil damage. 
Mount the unit high enough to be above 
the average accumulated area snowfall. 
The minimum height must be 18 inches. 
DO NOT install unit in the following
locations:
Near an obstacle that will block air inlets 
and outlets.
Near a public street, crowded areas, or 
where noise from the unit will disturb 
others. 
Near animals or plants that could be 
harmed by hot air discharge. 
Near any source of combustible gas. 
In a location that is exposed to large 
amounts of dust.
In a location exposed to excessive 
amounts of salty air. 
In a location that exposes the unit to 
large amounts of forced water. 
Fig. 6.1
6
Outdoor Unit Installation
Minimum Clearance
 above unit:
 24 in (60 cm)
Minimum Clearance
on the left side of 
unit: 12 in (30 cm)
Minimum Clearance
on the right side of 
the unit: 24 in (60 cm) 
Minimum Clearance 
in front of the unit: 
79 in (200 cm) 
Minimum Clearance
between the back of 
the unit and wall:
**Ground Installed:
 12 in (30 cm)
**Bracket Installed:
 6 in (15 cm)
NOTE: Install the unit by following local codes and 
regulations, these may slightly differ between 
regions.