Installation Guide
Page 36mrcool.com
Refrigerant Piping Connection
NOTE ON DRAIN HOSE PLACEMENT
Make sure to arrange the drain hose correctly
according to Fig. 7.3a.
 DO NOT kink the drain hose.
 DO NOT create a water trap.
 DO NOT put the end of the drain hose in 
 water or a container that will collect water. 
ENSURE UNUSED DRAIN HOLE IS PLUGGED
To prevent unwanted leaks, be sure that the 
factory installed hollow center rubber plug is
installed in the unused drain hole. 
Fig. 7.3a
Fig. 7.3b
Fig. 7.3c
Fig. 7.3d 
Make sure there are NO
kinks or dents in the 
hose to ensure proper 
drainage.
NOT CORRECT
DENTS  in the drain hose 
will create water traps.
NOT CORRECT
KINKS   in the drain hose 
will create water traps.
NOT CORRECT
DO NOT place the end 
of the drain hose in 
water or in containers 
that collect water. 
This will prevent 
proper drainage.
In this step you will connect the drain hose extension to 
the drain hose exiting from the indoor unit that is within 
the piping bundle you wrapped in the previous steps.
1. Securely connect the drain hose extension to the
 drain piping from the indoor unit. 
2. Using example Fig. 6.3a as a guide, make sure your
 drain pipe is run in a similar manner. The other
 examples in Fig 6.3 represent things you should
 avoid when installing your drain pipe.
3. Remove the air filter from the indoor unit and pour a
 small amount of water into the drain pan to ensure
 that the water exits the bottom of the unit and flows
 through the drain and drain pipe smoothly. 
Step 7: Connect Drain Pipe
CAUTION