Troubleshooting Guide
 Troubleshooting 13 
17
Indoor unit A evaporator outlet 
temperature (T2BA)
If the temperature is lower than -9°C, the digital display 
shows “-9.” If the temperature is higher than 70°C, the digital 
display shows “70.” If the indoor unit is not connected, the 
digital display shows: “--”
18
Indoor unit B evaporator outlet 
temperature (T2BB)
19
Indoor unit C evaporator outlet 
temperature (T2BC)
20
Indoor unit D evaporator outlet 
temperature (T2BD)
21
Indoor unit E evaporator outlet 
temperature (T2BE)
22
Indoor unit A room 
temperature (T1A)
If the temperature is lower than 0°C, the digital display shows 
“0.” If the temperature is higher than 70°C, the digital display 
shows “70.” If the indoor unit is not connected, the digital 
display shows: “--”
23
Indoor unit B room 
temperature (T1B)
24
Indoor unit C room 
temperature (T1C)
25
Indoor unit D room 
temperature (T1D)
26
Indoor unit E room 
temperature (T1E)
27
Indoor unit A evaporator 
temperature (T2A)
If the temperature is lower than -9°C, the digital display shows 
“-9.” If the temperature is higher than 70°C, the digital display 
shows “70.” If the indoor unit is not connected, the digital 
display shows: “--”
28
Indoor unit B evaporator 
temperature (T2B)
29
Indoor unit C evaporator 
temperature (T2C)
30
Indoor unit D evaporator 
temperature (T2D)
31
Indoor unit E evaporator 
temperature (T2E)
32
Condenser pipe temperature 
(T3)
33
Outdoor ambient temperature 
(T4)
34
Compressor discharge 
temperature (TP)
The display value is between 30°–129°C. If the temperature 
is lower than 30°C, the digital display shows “30.” If the 
temperature is higher than 99°C, the digital display shows 
single and double digits. For example, if the digital display 
shows “0.5”, the compressor discharge temperature is 105°C.
35 AD value of current The display value is a hex number.
For example, the digital display tube shows “Cd”, it means AD 
value is 205.
36 AD value of voltage