Troubleshooting Guide
 Troubleshooting 16 
22
Indoor unit A room 
temperature (T1A)
If the temperature is lower than 0°C, the digital display shows 
“0.” If the temperature is higher than 70°C, the digital display 
shows “70.” If the indoor unit is not connected, the digital 
display shows: “--”
23
Indoor unit B room 
temperature (T1B)
24
Indoor unit C room 
temperature (T1C)
25
Indoor unit D room 
temperature (T1D)
26
Indoor unit E room 
temperature (T1E)
27
Indoor unit A evaporator 
temperature (T2A)
If the temperature is lower than -9°C, the digital display shows 
“-9.” If the temperature is higher than 70°C, the digital display 
shows “70.” If the indoor unit is not connected, the digital 
display shows: “--”
28
Indoor unit B evaporator 
temperature (T2B)
29
Indoor unit C evaporator 
temperature (T2C)
30
Indoor unit D evaporator 
temperature (T2D)
31
Indoor unit E evaporator 
temperature (T2E)
32
Condenser pipe temperature 
(T3)
33
Outdoor ambient temperature 
(T4)
34
Compressor discharge 
temperature (TP)
The display value is between 30–129°C. If the temperature 
is lower than 30°C, the digital display shows “30.” If the 
temperature is higher than 99°C, the digital display shows 
single and double digits. For example, if the digital display 
shows “0.5”, the compressor discharge temperature is 105°C.
35 AD value of current The display value is a hex number.
For example, the digital display tube shows “Cd”, it means AD 
value is 205.
36 AD value of AC voltage
37 AD value of DC voltage
38
EXV open angle for A indoor 
unit
Actual data/4.
If the value is higher than 99, the digital display shows single 
and double digits.
For example, if the digital display shows “2.0”, the EXV open 
angle is 120×4=480p.
39
EXV open angle for B indoor 
unit
40
EXV open angle for C indoor 
unit
41
EXV open angle for D indoor 
unit
42
EXV open angle for E indoor 
unit
43 MVI valve open angle
44 EVI valve open angle