Use and Care Manual
 Page 18
mrcool.com
•
 CAUTION
•
To prevent wall damage, use a stud finder to
locate studs to mount the units to.
A minimum pipe run of 9.8 ft (3 m) is required to 
minimize vibration & excessive noise.
Two of the A, B, and C air circulation pathways of 
the outdoor unit must be free from obstructions 
at all times (Refer to illustration).
This illustration is for demonstration purposes only.
The actual shape and size of your air conditioner 
may vary.
NOTE: The installation of this system must be 
performed in accordance with the requirements 
of local and national standards. These could be 
different based on the region it is being 
installed in.
•
•
Safety Precautions 
1
2
3
4
1
Installation plate
Mounting screw 
ST3.9
× 25-C-H
Clip anchor
(1)
Remote 
controller 
holder
4 3 5 
2
Air-break Switch
Drainage 
Pipe
Air-break 
Switch
Outdoor Unit
Power Cable
4
Installation Diagram
One-Two
One-Three
One-Four
One-Five
More than 
24 in 
(60cm)
More than 
24 in 
(60cm)
More 
than 12 in 
(30 cm)
More than 
79 in
 (200 cm)
More than 
12 in 
(30 cm)
More than 
4.7 in (12 cm)
More than 6 in 
(15 cm)
More than 
4.7 in (12 cm)
More than 
4.7 in (12 cm)
5
More than 
4.7 in (12 cm)
Additional Line Sets & Coupler Kit
If you find the default line set lengths are not 
sufficient for your application, additional line 
sets are available for purchase. You will also 
need a coupler kit (pictured below), which 
allows line sets to be connected together. The 
coupler kit is installed and checked for leaks by 
following the same steps described in this 
manual for connecting the line set to the 
indoor air handler (Refer to Section 7: 
Refrigerant Piping Connections for these steps). 
Fig. 4.1