Troubleshooting Guide
 Troubleshooting 26 
Part requiring 
replacement
Error Code
PC 40 EC 72 PC 43 PC 45 (O)PC 06 (O)PC 0A (O)PC 30
PC 03/
(O)PC 31
Outdoor PCB
x
Outdoor fan motor x x x x
T3 Sensor x x x x x x x
T4 Sensor x x x x x x x x
TP Sensor x x x x x x x
T2B Sensor x x x x x x x x
Reactor or inductance x x x x x x x x
Compressor x x x x x x x
IPM module board x x x x x x x
Bridge rectifier x x x x x x x x
PFC module x x x x x x x x
Additional refrigerant x x x x x
Electric control box x x x x x x x
High pressure switch x x x x x x x
Low pressure switch x x x x x x x
Note:  For  certain  models,  outdoor  PCB  could  not  be  removed  separately.  In  this  case,  the  outdoor  electric 
control box should be replaced as a whole.