Troubleshooting Guide
 Troubleshooting 33 
8.4  EH 60 / EH 61 / EC 53 / EC 52 / EC 54 / EC 56 / (ODU) EC 50 (Open circuit or short circuit of 
temperature sensor diagnosis and solution) 
Description: If the sampling voltage is lower than 0.06V or higher than 4.94V, the LED displays the failure code.
Recommended parts to prepare:
•   Connection wires
•   Sensors
•   PCB
Troubleshooting and repair:
Check the connection between 
temperature sensor and PCB. 
Replace PCB 
Is it within acceptable 
parameters? 
Is it properly wired? Ensure proper connections.NO
Measure  the resistance value 
of the sensor.
YES
Replace the sensor.NO
YES
Note:  For  certain  models,  outdoor  PCB  could  not  be  removed  separately.  In  this  case,  the  outdoor  electric 
control box should be replaced as a whole. This picture and the value are only for reference, actual appearance 
and value may vary