The Olympus Series is NOT designed for amateur installation. Installation SHOULD be performed by an authorized technician. Please read this manual carefully before installation and keep it for future reference. Installation Manual Olympus Series Single (Hyper Heat & E Star) & Multi-Zone Models Due to updates and constantly improving performance, the information and instructions within this manual are subject to change without notice. Please visit www.mrcool.
Contents ! Safety Precautions .................................. 3 1 Accessories ............................................... 5 2 Overview .................................................. 7 3 Indoor Unit Installation ...........11 1. Installation location.................................11 2. Attach mounting plate to wall...............12 3. Drill wall hole for connective piping.....13 4. Prepare refrigerant piping ....................14 5. Connect drain hose.................................15 6.
Contents 5 Refrigerant Piping Connection ...................... 27 A. Note on Pipe Length ............................................................. 27 B. Connection Instructions –Refrigerant Piping .................. 27 1. Cut pipe .............................................................................. 27 2. Remove burrs ................................................................... 28 3. Flare pipe ends ................................................................. 28 4. Connect pipes ..
Safety Precautions Safety Precautions Read Before Installation ! Incorrect installation may cause serious damage or injury. either a WARNING or CAUTION. This symbol indicates ignoring instructions may cause death or serious injury. WARNING This symbol indicates that ignoring instructions may cause personal injury, damage to the unit, or property damage. CAUTION This symbol indicates that you should NEVER perform the indicated action.
Safety Precautions 7. You must use an independent circuit to supply power. DO NOT connect other appliances to the same circuit. Insufficient electrical capacity or defects in electrical work can cause electrical shock and/or fire. 8. prevent external forces from damaging the terminal. Improper electrical connections may overheat, 9. All wiring must be properly arranged to ensure that the control board cover can close properly.
Accessories 1 Safety Precautions installation parts and accessories to install the air conditioner. Improper installation may result PART LOOKS LIKE... QUANTITY Mounting plate 1 Clip anchor 5 or 8 5 or 8 screw ST3.9 X 25 1 Remote control 2 controller holder Optional Parts Remote control holder 1 Dry battery AAA.LR03 2 1 (optional) Seal 1 Drain joint 1 Neoprene 1 (Sealant for Wall Sleeve) Page 5 mrcool.
Accessories PART LOOKS LIKE... QUANTITY Please read this manual carefully before installation and keep it for future reference. Owner’s Manual 1 Owner’s Manual Olympus Series For more details visit www.MrCool.com Please read this manual carefully before installation and keep it for future reference. Installation Manual 1 (this) Installation Manual Olympus Series Please read this manual carefully before installation and keep it for future reference.
2 Overview Front Panel Air inlet (rear) (with display) Indoor Unit (Interior / Air Handler) Smart Controller Module USB Port Wall Mounting Plate Air outlet (bottom) Drainage Pipe Refrigerant Piping Signal Cable Fresh Air Filter Remote Control Air inlet (rear) Air inlet (side) Remote Holder Outdoor Unit Power Cable Air outlet Outdoor Unit (Exterior / Condenser) Signal Cable Connection from Indoor Unit Refrigerant Pipe Connection and Stop Valve (under cover) Fig. 2.
Overview - Multi-Zone Wall-Mounted Handlers Ceiling Ducted Handlers 5-Zone 5-Zone 4-Zone 4-Zone 3-Zone 3-Zone 2-Zone 2-Zone Fig. 2.2 Indoor unit 1. Panel frame 2. Rear air intake grille 3. Front panel Fig. 2.3 Indoor unit 1. Air outlet 2. Air inlet 5. Horizontal louver 7. Vertical louver 8. Manual control button (behind) 9. Remote control holder 4. Electric control cabinet 5. Wire controller Outdoor unit 6. Drain hose, refrigerant pipe 7. Connective cable 8. Stop valve 9.
Overview - Multi-Zone Cassette Handlers 5-Zone 4-Zone 3-Zone 2-Zone Indoor unit 1. Drain pump (from indoor unit) 2. Drain hose 3. Air outlet 4. Air inlet 5. Air-in grill 6. Display panel 7. Remote control Outdoor unit 8. Refrigerant connecting pipe 9. Connective cable 10. Stop valve 11. Fan hood Page 9 Fig. 2.4 mrcool.
Table 2.1 Indoor units that can be used in combination Number of connected units 1-5 units Compressor stop/start frequency 3 minutes or more Stop time within ±10% of rated voltage Power source voltage voltage drop during start within ±15% of rated voltage interval unbalance within ±3% of rated voltage Table 2.2 Unit: ft/m 2 ZONE 3 ZONE 4 ZONE 5 ZONE Max. length for all rooms 131.2 ft/40 m 147.6 ft/45 m 262.5 ft/80 m 262.5 ft/80 m Max. length for one indoor unit 82.0 ft/25 m 82.
Installation Summary - Indoor Unit Indoor Unit Installation Installation Instructions – Indoor Unit DO NOT install unit in the following locations: Near any source of heat, steam, or combustible gas PRIOR TO INSTALLATION: Before installing the indoor unit, refer to the label on the product box to make sure that the model numbers of the indoor units match the model number of the outdoor unit.
Indoor Unit Installation Refer to the following diagram to ensure proper distance from walls and ceiling: Minimum Ceiling Clearance is 5.9 in(15 cm) >4.75 in (12 cm) >4.75 in (12 cm) For Ceilings Floor Clearance is 90.55 in(230 cm) For Ceilings Fig. 3.1 Floor Clearance is 78.55 in(200 cm) Step 2: Attach mounting plate to wall Step 3: Drill wall hole for connective piping The mounting plate is the device on which you will mount the indoor unit . 1.
Indoor Unit Installation Indoor Wall Outdoor 0.2 - 0.3 in (5 - 7 mm) 4.3in/11mm Right rear side refrigerant pipe hole refrigerant pipe hole 2.6in/65mm 2.6in/65mm Series 9K Models Fig.3.2 MOUNTING PLATE DIMENSIONS 4.3in/11mm plates. In order to ensure that you have ample room to mount the indoor unit, the diagrams to the right Right rear side refrigerant pipe hole refrigerant pipe hole 2.6in/65mm with the following dimensions: 2.
Indoor Unit Installation 3. Step 4: Prepare refrigerant piping The refrigerant piping is inside an insulating sleeve attached to the back of the unit. You must prepare the piping before passing it through the hole in the wall. Refer to the Refrigerant Piping Connection section of this manual for detailed instructions on insulating sleeve to reveal about 6 in (15 cm) of the refrigerant piping.
Indoor Unit Installation Make sure there are NO kinks or dents in the hose to ensure proper drainage. Step 5: Connect drain hose By default, the drain hose is attached to the left-hand side of unit (when you’re facing the back of the unit). However, it can also be attached to the right-hand side. 1. To ensure proper drainage, the drain hose must exit the unit on the same side as the refrigerant piping. 2. Fig. 3.6a to ensure a good seal and to prevent leaks. 3.
Indoor Unit Installation BEFORE PERFORMING ELECTRICAL WORK, READ THESE REGULATIONS 1. All wiring must comply with local and national electrical codes, and must be installed by a licensed electrician. 2. All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units. 3. If there is a serious safety issue with the power supply, stop work immediately.
Indoor Unit Installation Step 6: Connect signal cable TAKE NOTE OF FUSE SPECIFICATIONS The signal cable enables communication between the indoor and outdoor units and provides power to the indoor unit. A 16 gauge AWG signal cable (H07RN-F) is provided for the unit. The tables below are for reference.
Indoor Unit Installation 6. Feed the signal wire through this slot, from the DO NOT INTERTWINE SIGNAL CABLE WITH OTHER WIRES 7. Facing the front of the unit, match the wire While bundling these items together, do not intertwine or cross the signal cable with any other wiring. back of the unit to the front. colors with the labels on the terminal block, to its corresponding terminal. 2.
Indoor Unit Installation If refrigerant piping is already embedded in the wall, do the following: 1. Hook the top of the indoor unit on the upper hook of the mounting plate. 2. giving you enough room to connect the refrigerant piping, signal cable, and drain hose. Refer to Fig. 3.9 for an example. Connect drain hose and refrigerant piping (refer to Refrigerant Piping Connection section of this manual for instructions).
4 Indoor Unit Installation Outdoor Unit Installation Installation Instructions – Outdoor Unit 24 in(60cm) 24in (60 cm) above above Step 1: Select installation location Before installing the outdoor unit, you must choose an appropriate location. The following standards will help you choose an appropriate location.
Outdoor Unit Installation IN COLD CLIMATES In cold climates, make sure that the drain hose is as vertical as possible to ensure swift water drainage. If water drains too slowly, it Strong wind Fig. 4.3 Step 2: Install drain joint Base pan hole of outdoor unit Heat pump units require a drain joint. Before bolting the outdoor unit in place, you must install the drain joint at the bottom of the unit. Note that there are Seal Seal type of outdoor unit.
Outdoor Unit Installation Step 3: Anchor outdoor unit - single-zone (Hyper Heat & E Star) A Air Inlet D H Air Inlet B Air Outlet Fig. 4.6 W UNIT MOUNTING DIMENSIONS Prepare the installation base of the unit according to the dimensions below. Outdoor Unit Dimensions: inches (millimeters) O-HH-09-HP-C-230 31.50 in x 21.81 in x 13.11 in (800 mm x 554 mm x 333 mm) O-HH-12-HP-C-230 31.50 in x 21.81 in x 13.11 in (800 mm x 554 mm x 333 mm) 33.27 in x 27.64 in x 14.29 in (845 mm x 702 mm x 363 mm) 37.
Outdoor Unit Installation Step 3: Anchor outdoor unit - Multi-Zone W H H W Fig. 4.7 A D B Fig. 4.9 Fig. 4.8 Outdoor Unit Dimensions: inches (millimeters) Mounting Dimensions: inches (millimeters) 33.27 in x 27.64 in x 14.29 in (845 mm x 702 mm x 363 mm) 37.24 in x 31.89 in x 16.14 in (946 mm x 810 mm x 410 mm) 37.24 in x 31.89 in x 16.14 in (945 mm x 810 mm x 410 mm) 37.48 in x 52.48 in x 16.34 in (952 mm x 1333 mm x 415 mm) Width (A) Depth (B) 21.26 in (540 mm) 26.5 in (673 mm) 26.
Outdoor Unit Installation Step 4: Connect signal and power cables wall-mounted installation continued 6. Check that the mounting brackets are level. BEFORE PERFORMING ELECTRICAL WORK, READ THESE REGULATIONS 7. Carefully lift unit and place its mounting feet on the brackets. 1. All wiring must comply with local and national electrical codes, and must be installed by a licensed electrician. 8.
Outdoor Unit Installation PAY ATTENTION TO LIVE WIRE While crimping wires, make sure you clearly distinguish the Live (“L”) Wire from other wires. BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAINPOWER TO THE SYSTEM. 1.
Outdoor Unit Installation Wiring Diagram CAUTION numbers on the terminal Terminal L1(A) of outdoor must connect with terminal L1 on the indoor unit. 2-Zone models: L1 L2 L1 L2 3-Zone models: L1 L2 L1 L2 L1L2 L1L2 L1L2 L1 L2 L1L2 L1 L2 L1 L2 L1L2 L1L2 L1 L2 L1 L2 5-Zone models: 4-Zone models: L1 L2 L1 L2 L1 L2 L1L2 L1 L2 L1L2 L1 L2 L1 L2 L1 L2 L1L2 L1L2 mrcool.
65 Outdoor Unit Installation Refrigerant Piping Connection Refrigerant Piping Connection NOTE ON PIPE LENGTH Nominal Model < 15,000 R410A Inverter Split Air Conditioner 82 ft (25 m) 33 ft (10 m) 15,000 and < 24,000 98.5 ft (30 m) 66 ft (20 m) 24,000 and < 36,000 164 ft (50 m) 82 ft (25 m) 36,000 and 60,000 213 ft (65 m) 98.5 ft (30 m) 2. Connection Instructions – Refrigerant Piping than the measured distance. 3. Make sure that the pipe is cut at a perfect 90° angle. Refer to Fig. 5.
Refrigerant Piping Connection Flare nut DO NOT DEFORM PIPE WHILE CUTTING Be extra careful not to damage, dent, or deform the pipe while cutting. This will Copper pipe the unit. Step 2: Remove burrs Fig. 5.3 piping connection. They must be completely removed. 4. Remove PVC tape from ends of pipe when 1. Hold the pipe at a downward angle to prevent burrs from falling into the pipe. 5. The end of the pipe must extend beyond the 2. dimensions shown in the table below.
Refrigerant Piping Connection 6. Step 4: Connect pipes 7. When connecting refrigerant pipes, be careful not to use excessive torque or to deform the piping in 8. pipe, then the high-pressure pipe. inspect the end of the pipe for cracks and even MINIMUM BEND RADIUS Table 5.1: Flare Diameter When bending connective refrigerant piping, the minimum bending radius is 4 in (10 cm). See Fig 6.6. Flare Diameter (F) Pipe Diameter Min Ø 1/4 in (6.35 mm) Ø 0.3 in (8.3mm) Ø 3/8 in (9.52 mm) Ø 0.
Refrigerant Piping Connection Instructions for Connecting Piping to Indoor Unit 1. Align the center of the two pipes that you will connect. See Fig. 5.7. Indoor unit tubing Flare nut Valve cover Pipe Fig. 5.9 Fig. 5.7 2. hand. USE ADJUSTABLE WRENCH TO GRIP MAIN BODY OF VALVE 3. the unit tubing. T 4. according to the torque values in Table 5.2. Fig. 5.8 Instructions for Connecting Piping to Outdoor Unit 1. the side of the outdoor unit. (See Fig. 5.9) 2.
6 Air Evacuation Preparations and Precautions Air and foreign matter in the refrigerant circuit can cause abnormal rises in pressure, which can gauge to evacuate the refrigerant circuit, removing any non-condensable gas and moisture from the system. Evacuation should be performed upon initial installation and when unit is relocated.
Air Evacuation Low Pressure Main Valve High Pressure Main Valve “Suction” Low Pressure “Liquid” High Pressure Flare nut Valve stem Wrench Cap Valve body Fig. 6.2 Fig. 6.3 Note on Adding Refrigerant Some systems require additional charging depending on pipe lengths. The standard pipe length varies according to local regulations. For example, in North America, the standard pipe length is 25 ft (7.5 m). In other areas, the standard pipe length is 16 ft (5 m).
Refrigerant Piping Connection System Leak and Checks Electrical Gas Leak Checks Electrical Safety Checks WARNING – RISK OF ELECTRIC SHOCK ALL WIRING MUST COMPLY WITH LOCAL LAND NATIONAL ELECTRICAL CODES, AND MUST BE INSTALLED BY A LICENSED ELECTRICIAN. installed in accordance with local and national regulations, and according to the Installation Manual. BEFORE TEST RUN Check Grounding Work Gas Leak Checks Measure grounding resistance by visual detection and with a grounding resistance tester.
System Leak Checks Self Correction Function (Multi-Zone Models Only) Multi-Zone units have a self-check function for wiring-to-piping association errors. Press the "check switch" on the outdoor unit PCB board for 5 seconds until LED displays "CE". Approximately 5 to10 minutes after the switch is pressed, the "CE" will disappear when the wiring and piping are reassociated and the error is corrected.
Test Run Refrigerant Piping Connection 8 Before Test Run List of Checks to Perform Only perform test run after you have completed the following steps: No electrical leakage • Electrical Safety Checks the electrical system is safe and operating properly • Gas Leak Checks All electrical terminals properly covered not leaking Indoor and outdoor units are solidly installed pressure) valves are fully open All pipe connection points do not leak Test Run Instructions You should perform the Test Run for
Testing DOUBLE-CHECK PIPE CONNECTIONS During operation, the pressure of the refrigerant circuit will increase. This may reveal leaks that were not present during your initial leak check. Take time during the Test Run to double-check that all refrigerant pipe connection points do not have leaks. Refer to Gas Leak Check section for instructions. 5. After the Test Run is successfully complete, and Perform have PASSED, do the following: a. operating temperature. Manual control button b.
Refrigerant Piping Connection EU Disposal Guidelines 9 This appliance contains refrigerant and other potentially hazardous materials. When disposing of this appliance, the law requires special collection and treatment. DO NOT dispose of this product as household waste or unsorted municipal waste. When disposing of this appliance, you have the following options: • Dispose of the appliance at a designated municipal electronic waste collection facility.
Olympus Series Single (Hyper Heat & E Star) & Multi-Zone Models ELECTRICIAN and/or HVAC TECHNICIAN: LICENSE #: INSTALLATION DATE: INSTALLATION LOCATION: SERIAL NUMBER: Consult with the sales agency or manufacturer for details.