Specs

2
SAP ORDERING
NO.
CASING
DIMENSIONS (IN.)
RATED
HEATING
OUTPUT†
AFUE
ENERGY
STARR
HEATING AIRFLOW
COOLING
CFM
@0.5ESP
(in. W.C.)
MOTOR HP
SPEED TAPS
H D W (BTUH)
UPFLOW/
HORIZONTAL
DOWNFLOW
CFM‡
HEATING
ESP
(in. W.C.)
PG95SAS24026A 35 29.5 14.2 25,000 95.5% 95.0% None 675 0.10 440-775 1/4 - 4
PG95SAS30040A 35 29.5 14.2 39,000 95.5% 95.0% None 820 0.10 625-905 1/2 - 4
PG95SAS42060B 35 29.5 17.5 58,000 95.5% 95.0% None 980 0.12 650-1420 1/2 - 5
PG95SAS48080B 35 29.5 17.5 78,000 95.5% 95.0% None 1040 0.15 810-1600 3/4 - 5
PG95SAS60080C 35 29.5 21.0 78,000 95.5% 95.0% None 1695 0.15 1335-1970 1-5
PG95SAS42100C 35 29.5 21.0 97,000 95.5% 95.0% None 1510 0.20 915---1545 1/2 - 4
PG95SAS60100C 35 29.5 21.0 97,000 95.5% 95.0% None 1680 0.20 1345---2065 1-5
PG95SAS60120D 35 29.5 24.5 117,000 95.5% 95.0% None 2245 0.20 1320-2105 1-5
PG95SAS60140D 35 29.5 24.5 135,000 95.5% 94.4% None 2175 0.20 1290--- 2035 1-5
Capacity in accordance wi th DOE test procedures. Ratings are position dependent. See rating plate.
Heating CFM at factory default blower motor heating tap settings.
ESP --- External Static Pressure
PG95S FEATURES AND BENEFITS
HYBRID HEATR Dual Fuel system compatible This system
can provide more control over your monthly energy bills by
automatically selecting the most economical method of heating.
With HYBRID HEAT components, our system automatically
switches between the gas furnace and the electric heat pump as
outside temperatures change to maintain greater ef ficiency and
comfort than with any traditional single-source heating system.
The heat pump also delivers high-efficiency cooling in the summer.
Robust Igniter
MRCOOL
s unique SiN igniter is not only
physi
cally robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further enhances
the gas furnace reliability
and continues MRCOOL's tradition of
t
echnology leadership and innovation in providing a reliable and
durable product.
Reliable Heat Exchanger Design The aluminized steel, clam
shell primary heat exchanger was re--engineered to achieve greater
efficiency out of a smaller size. The first two passes of the heat
exchanger are based on the current 80% product, a design with
more than ten years of field-proven performance and success.
These innovations, paired with the continuation of a crimped,
no-weld seam create an efficient, robust design for this essential
component.
The condensing heat exchanger, a stainless steel fin and tube
design, is positioned in the furnace to extract additional heat.
Stainless steel coupling box componentry between heat exchangers
has exceptional corrosion resistance in both natural gas and
propane applications.
4-Way Multipoise Design One model for all applications
there is no need to stock special downflow or horizontal models
when one unit will do it all. The new heat exchanger design allows
these units to achieve the certified AFUE in all positions.
Direct or Single-pipe Venting, or Optional Ventilated
Combustion Air All sizes except the 26,000 BTUH model can
be vented for direct vent/two-pipe, ventilated combustion air, or
single-pipe applications. The 26,000 BTUH model can use the
same 2--pipe venting system using outside air for combustion, but
is not considered direct--vent. This provides added flexibility to
meet diverse installation needs.
Sealed Combustion System This furnace brings in combustion
air from outside the furnace, which results in especially quiet
operation. By sealing the entire combustion vestibule, the entire
furnace can be made quieter, not just the burners.
Monoport Burners The burners are specially designed and
finely tuned for smooth, quiet combustion and economical
operation.
Bottom Closure Factory--installed for side return; easily
removable for bottom return. The multi-use bottom closure can
also serve for roll-out protection in horizontal applications, and act
as the bottom closure for the optional return air base accessory.
Blower Access Panel Switch—Automatically shuts off 115-v
power to furnace whenever blower access panel is opened.
Quality Registration Our furnaces are engineered and
manufactured under an ISO 9001 registered quality system.
Certifications This furnace is CSA (AGA and CGA) design
certified for use with natural and propane gases. The furnace is
factory-- shipped for use with natural gas. A CSA listed gas
conversion kit is required to convert furnace for use with propane
gas. The efficiency is AHRI efficiency rating certified. This furnace
meets California Air Quality Management District emission
requirements.
PG95SAS