Specs
Table Of Contents
8
ELECTRICAL DATA
U N I T S I Z E ---
SERIES
(VOLTAGE)
V/PH
OPER VOLTS* COMPR FAN
MCA
MAX
FUSE** or
CKT BRK
AMPS
MAX MIN LRA RLA FLA
1 8 --- A ( N )
208/230/1 253 197
48.0 9.00 0.50 11.8 20
2 4 --- A ( N ) 62.9 10.90 0.60 14.2 25
3 0 --- A ( N ) 72.5 13.50 1.40 18.3 30
3 6 --- B ( N ) 75.0 15.10 1.10 20.0 30
4 2 --- A ( N ) 105.5 18.10 1.40 24.0 40
4 8 --- A ( N ) 108.0 19.00 1.40 25.2 40
6 0 --- A ( N ) 144.2 24.40 1.52 32.0 50
3 6 --- B ( P )
208/230/3 253 187
70.0 8.46 1.10 11.7 20
4 8 --- A ( P ) 123.0 10.44 1.40 14.5 25
6 0 --- A ( P ) 110.0 15.96 1.52 21.5 30
3 6 --- B ( E )
460---3 506 414
31.0 3.85 0.60 5.4 15
4 8 --- A ( E ) 60.0 6.00 0.77 8.3 15
6 0 --- A ( E ) 52.0 7.75 0.77 10.5 15
* Permissible limits of the voltage range at which the unit will operate satisfactorily
* * T i m e --- D e l a y f u se .
FLA --- F u l l L o a d Am p s
LRA --- L o c k e d R o t o r A m p s
M C A --- Minimum Circuit Amps
RLA --- RatedLoadAmps
NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2007 requirements of ASHRAE S tandards 90.1
A--WEIGHTED SOUND POWER
UNIT SIZE --- SERIES (VOL TAGE)
STANDARD
RATING
(dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125 250 500 1000 2000 4000 8000
1 8 --- A ( N ) 69 45 48 56 62 55 53 47
2 4 --- A ( N ) 76 46 56 59 63 63 60 55
3 0 --- A ( N ) 77 52 62 67 68 65 62 55
3 6 --- B ( N , P, E ) 77 51 62 66 69 64 61 53
4 2 --- A ( N ) 76 49 61 63 65 62 60 52
4 8 --- A ( N , P, E ) 79 53 66 69 71 67 64 57
6 0 --- A ( N ) 73 50 63 62 63 60 58 52
6 0 --- A ( P, E ) 76 52 62 63 66 65 59 57
NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).
A--WEIGHTED SOUND POWER WITH SOUND HOOD
UNIT SIZE --- SERIES (VOL TAGE)
STANDARD
RATING
TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125 250 500 1000 2000 4000 8000
1 8 --- A ( N ) 68 47 48 56 61 55 52 46
2 4 --- A ( N ) 74 47 57 59 62 61 58 51
3 0 --- A ( N ) 77 52 62 67 67 65 62 54
3 6 --- B ( N , P, E ) 76 52 62 66 67 64 60 52
4 2 --- A ( N ) 74 50 61 63 64 61 58 49
4 8 --- A ( N , P, E ) 79 54 66 69 70 67 64 56
6 0 --- A ( N ) 73 51 64 62 63 59 56 49
6 0 --- A ( P, E ) 76 52 62 63 66 65 59 57
NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE --- SERIES (VOL TAGE) REQUIRED SUBCOOLING ° F (° C)
1 8 --- A ( N ) 11 (6.1)
2 4 --- A ( N ) 11 (6.1)
3 0 --- A ( N ) 10 (5.6)
3 6 --- B ( N ) 10 (5.6)
3 6 --- B ( P, E ) 11 (6.1)
4 2 --- A ( N ) 10 (5.6)
4 8 --- A ( N , P, E ) 14 (7.8)
6 0 --- A ( N , P, E ) 15 (8.3)
HP ONLY REPLACEMENT WITH PISTON INDOORS
When the PH14*B is used as a replacement component in a system with a piston fan coil, use the indoor piston size specified below:
UNIT SIZE --- SERIES
PISTON SIZE
FB4CNF FFM FPMA
1 8 --- A 0.052 0.050 0.050
2 4 --- A 0.057 0.057 0.056
3 0 --- A 0.067 0.070 0.067
3 6 --- B 0.070 0.072 0.069
4 2 --- A 0.078
4 8 --- A 0.084
6 0 --- A
=N/A