Specification
5
PHYSI CAL DATA
UNIT SIZE 24040 24060 30040 30060 36060 36090 42060 42090
NOMINAL CAPACITY (ton) 2 2 2 --- 1 / 2 2 --- 1 / 2 3 3 3 --- 1 / 2 3 --- 1 / 2
SHIPPING WEIGHT lb.
SHIPPING WEIGHT (kg)
329
149
329
149
361
164
361
164
390
177
390
177
455
206
455
206
COMPRESSOR / QUANTITY Rotary / 1 Recip / 1 Scroll / 1
REFRIGERANT (R ---410A)
Quantity lb.
Quantity (kg)
5.3
2.4
5.3
2.4
5.5
2.5
5.5
2.5
8.2
3.7
8.2
3.7
6.2
2.8
6.2
2.8
REFRIGERANT METERING DEVICE Orifice TXV Orifice
ORIFICE ID i n. / mm .059 / 1.5 .059 / 1.5 .061 / 1.55 .061 / 1.55 N/A .073 / 1.85 .073 /1.85
OUTDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
1..21
11.9
1...21
11.9
1...21
13.6
1...21
13.6
1...21
18.8
1...21
18.8
1...21
13.6
1...21
13.6
OUTDOOR FAN
Nominal C FM
Diameter in.
Diameter (mm)
Motor Hp (Rpm)
2500
24
609.6
1/10 (810)
2500
24
609.6
1/10 (810)
2700
24
609.6
1/10 (810)
2700
24
609.6
1/10 (810)
3200
24
609.6
1/5 (810)
3200
24
609.6
1/5 (810)
3600
26
660.4
1/5 (810
3600
26
660.4
1/5 (810)
INDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
3...17
3.7
3...17
3.7
3...17
3.7
3...17
3.7
3...17
3.7
3...17
3.7
3...17
4.7
3...17
4.7
INDOOR BLOWER
Nominal Cool ing Airflow (Cfm)
Size in.
Size (mm.)
Motor HP (RPM)
800
800
1000
1000
1150
1150
1350
1350
800
10x10
254x254
1/2 (1050)
800
10x10
254x254
1/2 (1050)
1000
10x10
254x254
1/2 (1050)
1000
10x10
254x254
1/2 (1050)
1150
11x10
279.4x254
3/4 (1000)
1150
11x10
279.4x254
3/4 (1000)
1350
11x10
279.4x254
3/4 (1075)
1350
11x10
279.4x254
3/4 (1075)
FURNACE SECTION*
Burner Orifice No. (Qty...Drill Size)
1 Phase Natural Gas (Factory Installed)
1 Phase Propane Gas
3 Phase Natural Gas (Factory Installed)
3 Phase Propane Gas
2...44
2...55
3...44
3...55
2...44
2...55
2...44
2...55
3...44
3...55
2...38
2...53
3...44
3...55
2...38
2...53
3...38
3...53
3...38
3...53
3...44
3...55
2...38
2...53
3...38
3...53
3...38
3...53
HIGH --- PRESSURE SWITCH
(psig) Cut---out Reset (Auto)
650 +/-- 15
420 +/-- 25
LOSS--OF--CHARGE / LOW--PRESSURE
SWITCH (Liquid Line) (psig) cut-- out Reset
(auto)
20 +/-- 5
45 +/-- 10
N/A
RETURN --- AIR FILTERS†}
Throwaway Size in.
(mm)
2 each 20x12x1
508x305x25
1 each 24x14x1
610x356x25
24x15x1
610x406x25
*Based on a ltitude of 0 to 2000 ft (0---610 m).
{ Required filter sizes shown are based on the larger of the AHRI (Air Conditioning Heating and Refrigeration Institute) rated cooling airflow or the heating air-
flow velocity of 300 to 350 ft/minute for throwaway type. Air filter pressure drop for non---standard filters must not exceed 0.08 IN. W.C.
} If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity.
PY4G -- -- B