Specifications

Known issues with
firmware v4.7 fdr 35
58
6.13.5. Connected for Dual-Home, but configured as
Single-Home may cause inconsistent behavior.
(BZ#: 4341)
Description: A setup meant for Dual-Home operation using 3 EM316GRMAHSH boards, could be
configured (via CLI or MegaVision) to be Single-Home operation, even though the connection is meant
for Dual-Home operation.
After issuing homing singleco to change from a dual-homing to a single home, both CLI
and MegaVision will show CPEs connected/managed from both COs. This will lead to confusion to
understand which CO is actually managing the CPE. To avoid this confusion, better command to use is
no redundancy, which in turn will 'auto-adjust' the homing to singleco.
Suggested Work-Around: Issue no redundancy on both COs, instead of using homing
singleco .
Customer Impact: Minimal. Informational only.
Corrective Action: This issue will be addressed in future software upgrades.
6.13.6. Traffic counts shown on ports without link
(BZ#: 4285)
Description: Ports with no connection may show traffic count values when show statistics
is used.
Example: trunk port 2 may be disconnected but showing the same traffic count values as on trunk port
1. The same is true for user ports.
Example: user port 3 may be disconnected but showing the same traffic count values as on the port which
was set as the preferred port, port 4.
Suggested Work-Around: None. Since the underlying hardware has one set of counters for trunk
and user ports, the same numbers are shown for both port pairs.
Customer Impact: Minimal. Informational only.
Corrective Action: This issue will be addressed in future software upgrades.