D. TS700/100 - Fast-Ethernet System
Figure 1.6: TS700/100 Model Back Panel
Back Panel Description
Table 4: TS700/100 Back Panel Controls, Interfaces, and Indicators
Power
Power source Terminal Block (Main or UPS)
AC power supply (100 to 240 Vac) or DC power
supply (24 to 60 Vdc).
100Base-TX
Copper interface (RJ45) for STP cables.
MDI-X connection (TX: pins 3,6 and RX: pins 1,2).
Connection to the peripheral equipment.
This connector can be used for Power-over-Ethernet
(PoE) but only with the Low Voltage TereScope version
(TS100/A/FET/V3). The standard power for PoE is
36-57 Vdc. However, the TS700/100 can operate with
20-60 Vdc.
See appendix I.
Management
(Optional)
Connection to 10Base-T SNMP management
interface. (To be ordered separately)
Connectors
Dry Contacts There are 2 pairs of dry contact indicators available,
one for Air RX Link LED (Pins 1 and 2), and the
other for 100BaseT LED (Pins 3 and for). Dry
contacts are normally closed (25 ohms), and open in
an alarm condition