Instruction manual

• Press PAGE (UP arrows) or
RESET (DOWN arrows) to scroll
through the languages.
• Once the desired language
displays, press ON/OFF (OK).
• If a new language is selected, the
instrument prompts the user to
choose to display the combustible
gas readings as:
• percent Lower Explosive
Limit (LEL) Pentane
OR
• percent Methane.
Pressing the PAGE (LEL) button
causes the combustible readings to
display as 0-100% LEL.
Pressing the RESET (YES) button causes
the instrument to display combustible
readings as direct 0-5% Methane.
• The (FIGURE 2-7) display appears.
If PAGE (NO) is pressed, or no
buttons are pressed for five seconds,
the operating beep will be disabled.
If RESET (YES) is pressed, the
operating beep is enabled and the
instrument alarm sounds once every 30
seconds to indicate that the FiveStar
Alarm is turned ON. This beep does not
occur if YES is not selected.
• The (FIGURE 2-8) display appears.
• If YES is selected, the PEAK STEL TWA pages appear.
• If NO is selected,
the PEAK STEL TWA pages do not appear.
• If no button is pressed the unit maintains
the previous setting for these pages.
• The display moves to the "Set Time" page.
• The (FIGURE 2-9) display now appears.
Figure 2-6.
Scrolling through the
Language Options
Figure 2-7.
Operating Beep - No/Yes?
Figure 2-8.
Peak STEL TWA?
Instruction Manual Chapter 2, Using the FiveStar Alarm
FiveStar Alarm 2-3