Instruction manual

4. Remove the water trap filter and replace.
Removing Sampling Equipment
1. Turn OFF the FiveStar Alarm.
2. Unscrew the connector ring on the sampling line; remove
sampling line.
Keying Series Red/Series Green
Battery Packs
Instruments built after February, 1999 are designed to accept
keyed battery packs conforming to:
North American standards (marked "SERIES GREEN") or to
European/Australian standards (marked "SERIES RED").
Always match the battery pack to the corresponding instrument
by noting these SERIES GREEN and SERIES RED labels.
Instruments built prior to February, 1999 conform to the North
American standards and should only be used with SERIES
GREEN battery packs.
"
CAUTION
SERIES RED and SERIES GREEN battery packs are not
interchangeable; damage may occur to the instrument and/or
battery pack if the SERIES RED and SERIES GREEN battery
packs are interchanged.
To use a new SERIES GREEN battery pack with a North
American standard
instrument built before
February, 1999:
1. To verify that the
instrument was built to
conform with
North American standard
s, ensure that it has an
approval label listing
MET and/or MSHA.
2. Remove the key in the
battery pack (FIGURE
2-51) by prying it out of
Figure 2-51.
Key for SERIES GREEN Battery Pack
Instruction Manual Chapter 2, Using the FiveStar Alarm
FiveStar Alarm 2-29