NOTE: In colder temperatures, battery output may be
severely reduced. The following table shows
capacity reductions expected for replaceable
batteries at these temperatures.
Capacity Reductions Expected for Batteries at Colder Temperatures
TEMPERATURE NiCd NiMH AA ALKALINE AA LITHIUM
70
o
F (21
o
C) None None None None
32
o
F (0
o
C) 10% 20% 25% 15%
14
o
F (-10
o
C) 20% 30% 60% 40%
Approximate Battery Run Times
NORTH AMERICAN
APPROVED INSTRUMENT
FIVESTAR Alarm OPERATING TIME
(WITHOUT DERATING/ AT 20
o
C)
BATTERY TYPE WITHOUT PUMP WITH PUMP
Ni Cad Standard
10-12 hours 8-10 hours
NiMH Heavy-duty
18-21 hours 14-16 hours
Lithium
11 hours 9 hours
Alkaline
7 hours 5 hours
EN AND AUSTRALIAN
APPROVED INSTRUMENT
FIVESTAR Alarm OPERATING TIME
(WITHOUT DERATING/ AT 20
o
C)
BATTERY TYPE WITHOUT PUMP WITH PUMP
Ni Cad Standard
8 hours 6 hours
NiMH Heavy-duty
16-20 hours 13-16 hours
Chapter 4, Performance Specifications Instruction Manual
4-2 FiveStar Alarm