Instruction manual

Carbon Monoxide Sensor Specifications
Table 4-5. CARBON MONOXIDE (appropriate models only) -
Typical Performance Specifications
RANGE
2000 ppm CO
RESOLUTION
1 ppm CO
REPRODUCIBILITY
+2 ppm CO or 10% of reading, whichever is greater
RESPONSE TIME
90% of final reading in 30 seconds (normal temperature range)
Table 4-6. - CARBON MONOXIDE - Cross Reference Factors for
FiveStar Calibration Using Calibration Cylinder (P/N 478191)
or (P/N 804770)
NOTE: Data is presented as the indicated output in ppm,
which would result from the application of 100 ppm of the test gas.
TEST GAS (100 PPM) EQUIVALENT PPM
Carbon Monoxide (CO)
100 +9
Hydrogen Sulfide (H
2
S)
1 +6
Sulfur Dioxide (SO
2
)
0 +1
Nitrogen Dioxide (NO
2
)
2 +6
Nitric Oxide (NO)
70 +10
Chlorine (Cl
2
)
1 +8
Ammonia (NH
3
)
2 +4
Hydrogen Chloride (HCl)
3 +2
Ethylene (C
2
H
4
)
80 +9
Hydrogen Cyanide (HCN)
0 +1
Methane (CH
4
)
0 +0
Ethanol (EtOH)
4 +5
Hydrogen (H
2
)
70 +26
Chlorine Dioxide (ClO
2
)
0
NOTE: Unsaturated hydrocarbons, such as ethylene, will have a significant positive reaction
with the CO sensors
Instruction Manual Chapter 4, Performance Specifications
FiveStar Alarm 4-5