Issue Date: 2003-09-25 Page 1 of 1 Report Reference # E203413-A17-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Home Plug Device MS-6821 Rating(s): 100 - 240 Vac, 47 - 63 Hz, 0.1 A. Standards: IEC60950, Third Edition (1999) Applicant Name and Address: MICRO-STAR INTERNATIONAL CO LTD 69 LI-DE ST CHUNG HO CITY TAIPEI HSIEN TAIWAN Factory Location(s): 1. MICRO-STAR INTERNATIONAL CO., LTD. 488 BAN NAN ST. CHUNG HO CITY TAIPEI HSIEN 235 TAIWAN 2.
Issue Date: 2003-09-25 TRF No.
Issue Date: 2003-09-25 Page 2 of 42 Report Reference # E203413-A17-CB-1 Particulars: test item vs. test requirements Equipment mobility.................................................: direct plug-in Operating condition................................................: continuous Mains supply tolerance (%).....................................: +6%, -10% Test for IT power systems.......................................: No IT testing, phase-phase voltage (V) ........................
Issue Date: 2003-09-25 Page 3 of 42 Report Reference # E203413-A17-CB-1 General Product Information: Report Summary All applicable tests according to the referenced standard(s) have been carried out. Product Description Electronic Component mounted on PWB and housed with plastic enclosure.
Issue Date: 2003-09-25 Page 5 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 1 GENERAL Pass 1.5 Components Pass 1.5.1 Comply with IEC 950 or relevant component standard (see appended table 1.5.1) Pass 1.5.2 Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this Standard.
Issue Date: 2003-09-25 Page 6 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 1.6 Power Interface 1.6.1 AC power distribution systems AC power distribution systems are classify as TN. Pass 1.6.2 Input current The steady state input current of the equipment did not exceed the RATED CURRENT by more than 10% under NORMAL LOAD. Pass Pass (see appended table 1.6.2) 1.6.3 Voltage limit of hand-held equipment Not hand-held equipment. 1.6.
Issue Date: 2003-09-25 Page 7 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark 1.7 Marking and Instructions 1.7.1 Power rating Verdict Pass Rating marking readily visible to operator. See below for details. Rated voltage(s) or voltage range(s) (V) ..............: 100 - 240 Vac Pass Pass Symbol for nature of supply for d.c. .....................: AC Source N/A Rated frequency or frequency range (Hz).............
Issue Date: 2003-09-25 Page 8 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 1.7.8.2 Colours..............................................................: No indicators, switches and other controls affecting safety provided. 1.7.8.3 Symbols according to IEC 60417.........................: N/A 1.7.8.4 Markings using figures ........................................: N/A 1.7.9 Isolation of multiple power sources ......................
Issue Date: 2003-09-25 Page 9 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 2.1 Protection from electric shock and energy hazards Pass 2.1.1 Protection in OPERATOR access areas Pass 2.1.1.1 Access to energized parts No operator access to energized parts. Pass Test by inspection ..............................................: No operator access to energized parts. Pass Test with test finger ..........................................
Issue Date: 2003-09-25 Page 10 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test 2.2 SELV Circuits 2.2.1 General requirements 2.2.2 Voltages under normal conditions (V) ..................: All accessible voltages are less than 42.4 Vp or 60 V dc and are classified as SELV. Pass 2.2.3 Voltages under fault conditions (V)......................: Under fault conditions voltages never exceed 71V peak and 120Vdc and do not exceed 42.4V peak or 60V dc for more than 0.
Issue Date: 2003-09-25 Page 11 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 2.4 Limited Current Circuits N/A 2.4.1 General requirements N/A 2.4.2 Limit values N/A Frequency (Hz) ..................................................: - Measured current (mA).......................................: - Measured voltage (V).........................................: - Measured capacitance (µF) ................................: - 2.4.
Issue Date: 2003-09-25 Page 12 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark 2.6 Provisions for Earthing and Bonding N/A 2.6.1 Protective earthing N/A 2.6.2 Functional earthing N/A 2.6.3 Protective earthing and protective bonding conductors N/A 2.6.3.1 Size of protective earthing conductors N/A Rated current (A), cross-sectional area (mm²), AWG .................................................................: 2.6.3.
Issue Date: 2003-09-25 Page 13 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 2.7 Overcurrent and Earth Fault Protection in Primary Circuits Pass 2.7.1 Basic requirements Pass The building installation is considered as protection in Primary Circuits. Instructions when protection relies on building installation Pass 2.7.2 Faults not covered in 5.3 Pass 2.7.
Issue Date: 2003-09-25 Page 14 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 2.9 Electrical Insulation 2.9.1 Properties of insulating materials See appended table 1.5.1 Pass 2.9.2 Humidity conditioning Humidity treatment performed to 48 hrs in condition: Pass Pass 93%, 25 Degree C 2.9.3 Requirements for insulation Electric strength test conducted after the humidity treatment. No flash over or breakdown of insulation.
Issue Date: 2003-09-25 Page 15 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 2.10 Clearances, Creepage Distancesand Distances Through Insulation Pass 2.10.1 General Pollution degree 2 applicable. Pass 2.10.2 Determination of working voltage (see appended table 2.10.3 and 2.10.4) Pass 2.10.3 Clearances (see appended table 2.10.3 and 2.10.4) For Functional Insulat ion, see 5.3.4. Pass 2.10.3.1 General 2.10.3.
Issue Date: 2003-09-25 Page 16 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict Two wires in contact inside component; angle between 45° and 90° Prevented by insulating sleeving Pass 2.10.6 Coated printed boards No coated printed wiring boards. N/A 2.10.6.1 General N/A 2.10.6.2 Sample preparation and preliminary inspection N/A 2.10.6.3 Thermal cycling N/A 2.10.6.4 Thermal ageing (°C) ...........................................
Issue Date: 2003-09-25 Page 17 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test 3.1 General Pass 3.1.1 Current rating and overcurrent protection Pass 3.1.2 Protection against mechanical damage The wires are routed away from sharp edges and parts which could damage insulation. Pass 3.1.3 Securing of internal wiring The wires are positioned in such a manner that prevents excessive strain, loosening of terminal connections and damage of conductor insulation.
Issue Date: 2003-09-25 Page 18 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 3.2 Connection to A.C. Mains Supplies Pass 3.2.1 Means of connection ..........................................: The unit is provided with a means for direct plug-in. Pass 3.2.2 Multiple supply connections Single mains supply. N/A 3.2.3 Permanently connected equipment The equipment is not permanently connected.
Issue Date: 2003-09-25 Page 19 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test 3.3 Wiring Terminals for Connection of External Conductors N/A 3.3.1 Wiring terminals N/A 3.3.2 Connection of non-detachable power supply cords N/A 3.3.3 Screw terminals N/A 3.3.4 Rated current (A), cord/cable type, cross-sectional area (mm²) .........................................................: N/A 3.3.5 Rated current (A), type and nominal thread diameter (mm) ...........
Issue Date: 2003-09-25 Page 20 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark 3.5 Interconnection of Equipment 3.5.1 General requirements Verdict Pass This equipment is only considered for connection to SELV. Pass Ref. to 2.2 for other details. 3.5.2 Types of interconnection circuits .........................: Interconnection circuits are SELV CIRCUITS. 3.5.3 ELV circuits as interconnection circuits 4 PHYSICAL REQUIREMENTS 4.
Issue Date: 2003-09-25 Page 21 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 4.2 Mechanical strength 4.2.1 General See below. Pass 4.2.2 Steady force test, 10 N 10N were applied to components. Pass Pass No energy or other hazards. 4.2.3 Steady force test, 30 N No internal enclosure. 4.2.4 Steady force test, 250 N 250N were applied to the outer enclosure. N/A Pass No energy or other hazards. 4.2.5 Impact test 4.2.
Issue Date: 2003-09-25 Page 22 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 4.3 Design and Construction 4.3.1 Edges and corners 4.3.2 Handles and manual controls; force (N) ...............: N/A 4.3.3 Adjustable controls N/A 4.3.4 Securing of parts N/A 4.3.5 Connection of plugs and sockets Pass 4.3.
Issue Date: 2003-09-25 Page 23 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test 4.5 Thermal Requirements 4.5.1 Temperature rises Result - Remark Verdict Pass (see appended table 4.5) Pass Normal load condition per Annex L......................: Operated in the most unfavorable way of operation given in the operating instructions until steady conditions established. Pass 4.5.2 Resistance to abnormal heat Pass 4.6 Openings in Enclosures 4.6.
Issue Date: 2003-09-25 Page 24 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 4.7 Resistance to Fire 4.7.1 Reducing the risk of ignition and spread of flame 4.7.2 Conditions for a fire enclosure 4.7.2.1 Parts requiring a fire enclosure 4.7.2.2 Parts not requiring a fire enclosure 4.7.3 Mat erials 4.7.3.1 General See below. Pass 4.7.3.2 Materials for fire enclosures V-1 minimum. Pass 4.7.3.
Issue Date: 2003-09-25 Page 25 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 5.1 Touch current and protective conductor current 5.1.1 General See below. Pass 5.1.2 Equipment under test (EUT) Equipment designed for connection to only one power source. Pass 5.1.3 Test circuit Single phase equipment intended only for connection to star TN or TT system. Pass 5.1.
Issue Date: 2003-09-25 Page 26 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 5.3 Abnormal Operating and Fault Conditions 5.3.1 Protection against overload and abnormal operation (see appended table 5.3) 5.3.2 Motors No motors. 5.3.3 Transformers Transformers are constructed in accordance with the applicable Clause and Annex C. Pass Pass N/A Pass (see appended Annex C) 5.3.4 Functional insulation....................................
Issue Date: 2003-09-25 Page 27 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict 6.2 Protection of Equipment Users From Overvoltages on Telecommunication Networks N/A 6.2.1 Separation requirements N/A 6.2.2 Electric strength test procedure N/A 6.2.2.1 Impulse test N/A 6.2.2.2 Steady-state test N/A 6.2.2.3 Compliance criteria N/A 6.3 Protection of Telecommunication Wiring System From Overheating N/A Max. output current (A) ....
Issue Date: 2003-09-25 Page 28 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see 4.7.3.2 and 4.7.3.4) A.2.1 Samples, material ..............................................: - Wall thickness (mm) ...........................................: - A.2.6 A.2.
Issue Date: 2003-09-25 Page 29 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test A.4 Hot wire ignition test (see 4.7.3.2) A.4.1 Samples, material ..............................................: - Wall thickness (mm) ...........................................: - A.4.5 Result - Remark Verdict N/A Compliance criteria N/A Sample 1 ignition time (s) ...................................: - Sample 2 ignition time (s) ...................................
Issue Date: 2003-09-25 Page 30 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict A.8 Flammability test for classifying materials HB A.8.1 Samples, material ..............................................: - Sample thickness (mm) ......................................: - A.8.2 Conditioning of samples; temperature (°C) ...........: N/A A.8.4 Test procedure N/A A.8.5 Compliance criteria N/A A.8.6 Permitted retest N/A A.
Issue Date: 2003-09-25 Page 31 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and 5.3.2) N/A B.1 General requirements N/A Position ................................ .............................: - Manufacturer ................................ .....................: - Type..................................................................: - Rated values....................
Issue Date: 2003-09-25 Page 32 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark C ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3) Verdict Pass Position ................................ .............................: (see appended table 1.5.1) - Manufacturer ................................ .....................: (see appended table 1.5.1) - Type..................................................................: (see appended table 1.5.
Issue Date: 2003-09-25 Page 33 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) Metal used .........................................................: N/A - K ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.7) N/A K.1 Making and breaking capacity N/A K.2 Thermostat reliability; operating voltage (V)..........: N/A K.3 Thermostat endurance test; operating voltage (V) : N/A K.
Issue Date: 2003-09-25 Page 34 of 42 Report Reference # E203413 -A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark 1.5.1 TABLE: list of critical components Verdict Pass object/part No. manufacturer/ trademark type/model technical data standard mark(s) of 1 conformity ) 01. PWB -- -- UL796 UL, -- 02. Varistor (R31) 03. Transient Voltage Suppressors (D4, D5) 04. X-Cap. (C39) Centra Science Corp. Concord Semiconductor Corp.
Issue Date: 2003-09-25 Page 35 of 42 Report Reference # E203413 -A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark 05-2 Transformer Core -- -- 05-3. Transformer Tubing Fluo Tech Industries Co., Ltd. TFL 05-4. Transformer Glue Dow Corning Corp. 3165 05-5. Transformer Heat shrink Tubing -- -- 06. Power Module Universal Microelectronics Co., Ltd. UP0051A-05 07. Insulator Formex, Div Of Illinois Tool Works Inc, Formerly FORMEX GK 08. Shielding -- -- 09.
Issue Date: 2003-09-25 Page 36 of 42 Report Reference # E203413 -A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark 11. Internal wiring -- -- 12. Interconnecting Cable (Optional) -- -- 13. Insulating Tubing/Sleeving -- -- 1 FEP, PTFE, UL758 PVC, TFE, neoprene, polyamide or marked VW -1; minimum 300 V, 80 degree C. Minimum 80 UL758 degree C, 30 V, maximum 3.05 m long, jacketed, VW-1 or FT-1.
Issue Date: 2003-09-25 Page 37 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test 1.6.2 TABLE: electrical data (in normal conditions) fuse # --------- I rated (A) --0.1 0.1 0.1 0.1 --- Result - Remark U (V) P (W) 90/47Hz 90/63Hz 100/47Hz 100/63Hz 240/47Hz 240/47Hz 254/47Hz 254/63Hz 3.0 3.1 2.9 2.9 2.5 2.4 2.8 2.
Issue Date: 2003-09-25 Page 38 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark 4.5 TABLE: temperature rise measurements Verdict Pass test voltage (V) ................................................. : 63 HZ, 90 Vac, 2.5hrs, Horizontal / 254 Vac, 2.5hrs, Horizontal / 90 Vac, 2hrs, Vertical / 254 Vac, 2hrs, Vertical t1 (°C) ............................................................. : -- — t2 (°C) ..................................................
Issue Date: 2003-09-25 Page 39 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark 4.5.2 TABLE: ball pressure test of thermoplastics Verdict Pass allowed impression diameter (mm)..................... : 2 mm — part test temperature (°C) Enclosure, GE Plastics/945, 2.4 mm 125 impression diameter (mm) 1 supplementary information: -- 5.
Issue Date: 2003-09-25 Page 40 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test Result - Remark Verdict supplementary information: Comments Key: NO - Normally operated NB - No indication of dielectric breakdown NC - Cheesecloth remained intact NT - Tissue paper remained intact CT - Constant temperatures were obtained A.6.5 TABLE: flammability test for classifying materials V-0, V-1 or V-2 sample No. / ref.
Issue Date: 2003-09-25 Page 41 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test A.7.9 TABLE: flammability re -test for classifying foam materials HBF sample No. flame time (s) Result - Remark glow time (s) flaming/glowing distance from the end (mm) Verdict N/A comment (for A.7.7 burning rate mm/min) supplementary information: A.8.5 TABLE: flammability test for classifying materials HB sample No.
Issue Date: 2003-09-25 Page 42 of 42 Report Reference # E203413-A17-CB-1 IEC 60950 Clause Requirement + Test sample No. Result - Remark test bars flaming + glowing time (s) Verdict test plaques burning distance (mm) position flaming + glowing time (s) burning distance (mm) supplementary information: TRF No.
Issue Date: 2003-09-25 Page 1 of 25 Report Reference # Enclosure National Differences (Total 25 Pages including this Cover Page) Austria** Belgium** Czech Republic* Denmark Finland France** Germany Greece** Group Hungary* Ireland Italy** Japan Netherlands** Norway Poland* Slovakia* Slovenia* South Africa* Spain Sweden Switzerland USA / Canada Yugoslavia* * No National Differences Declared ** Only Group Differences UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 2 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict Denmark - Differences to IEC60950, Third Edition (1999) 1.2.4.1 Certain types of Class I appliances (see sub-clause 3.2.1) may be provided with plug not establishing earthing continuity when inserted into Danish socket-outlets. N/A 1.7.
Issue Date: 2003-09-25 Page 3 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test 3.2.1 Result - Remark Supply cord of single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to the Heavy Current Regulations, Section 107 -2-D1.
Issue Date: 2003-09-25 Page 4 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict Germany - Differences to IEC60950, Third Edition (1999) 1.7.12 Directions for use with rules to prevent certain hazards for (among others) maintenance of the technical labour equipment, also for imported technical labour equipment shall be written in the German language. NOTE: Of this requirement, rules for use even only by service personnel are not exempted.
Issue Date: 2003-09-25 Page 5 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test H.
Issue Date: 2003-09-25 Page 6 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict Group - Differences to IEC60950, Third Edition (1999) 2.7.
Issue Date: 2003-09-25 Page 7 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test 3.2.5 Result - Remark In table 3B, replace the first four lines by the following: Verdict N/A Up to and including 6 0.75 1) Over 6 up to and including 10 0.75 2) 1.0 Over 10 up to and including 16 1.0 3) 0.5 In the Conditions applicable to table 3B delete the words "in some countries" in condition 1. In NOTE 1, delete the second sentence. 3.3.
Issue Date: 2003-09-25 Page 8 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Q Result - Remark Add the following notes for the standards indicated: Verdict Pass IEC 60127 series NOTE. Harmonized as EN 60127 series (not modified) IEC 60529 NOTE: Harmonized as EN 60529: 1991 (not modified) IEC 61032 NOTE: Harmonized as EN 61032: 1998 (not modified) Ireland - Differences to IEC60950, Third Edition (1999) 3.2.
Issue Date: 2003-09-25 Page 9 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict Japan - Differences to IEC60950, Third Edition (1999) 1.2.4.101 Addition: Definition of CLASS 0I EQUIPMENT N/A 1.2.12.1 Replacement: FLAMMABILITY CLASSIFICATION OF MATERIALS: "The recognition of the burning behaviour of materials and their ability to extinguish if ignited. Materials are classified as in 1.2.12.2 to 1.2.12.9, and 1.2.12.
Issue Date: 2003-09-25 Page 10 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict 2.6.101 Addition:Earthing of CLASS 0I EQUIPMENT Plugs with a lead wire for earthing not used for equipment having a rated voltage exceeding 150 V N/A 2.6.101 For plugs with a lead wire for earthing, the lead wire is not earthed by a clip N/A 2.6.
Issue Date: 2003-09-25 Page 11 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict Annex A Add the subclause A.101titled: "Flammability tests for classifying materials VTM" and the following: "Thin sheet materials shall comply with ISO 9773" N/A Annex G Add to the Note for Table G.1. "2.
Issue Date: 2003-09-25 Page 12 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict Norway - Differences to IEC60950, Third Edition (1999) 1.5.8 Due to the IT power system used (see annex V, figure V.7), capacitors are required to be rated for the applicable phase-to-phase voltage ( 230 V). N/A 1.7.
Issue Date: 2003-09-25 Page 13 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test 6.1.2.1 Result - Remark If this insulation forms part of a semiconductor component e.g.
Issue Date: 2003-09-25 Page 14 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict Spain - Differences to IEC60950, Third Edition (1999) 3.2.1 Supply cords of single-phase equipment having a rated current not exceeding: - 2.
Issue Date: 2003-09-25 Page 15 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict Sweden - Differences to IEC60950, Third Edition (1999) 1.5.1 Add the following: NOTE: Switches containing mercury such as thermostats, relays and level controllers are not allowed. N/A 1.7.
Issue Date: 2003-09-25 Page 16 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test 6.1.2.2 Result - Remark The exclusions are applicable for PERMANENTLY CONNECTED EQUIPMENT and PLUGGABLE EQUIPMENT TYPE B only. Verdict N/A Switzerland - Differences to IEC60950, Third Edition (1999) 1.5.1 Add the following: N/A NOTE: Switches containing mercury such as thermostats, relays and level controllers are not allowed. 1.7.15 Annex 4.10 of SR 814.
Issue Date: 2003-09-25 Page 17 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict USA / Canada - Differences to IEC60950, Third Edition (1999) 1.1 Equipment able to be installed in accordance with the National Electrical Code ANSI/NFPA 70 and the Canadian Electrical Code, Part1. Pass 1.1.1 Equipment able to be installed in accordance with ANSI/NFPA 75 and NEC Art.
Issue Date: 2003-09-25 Page 18 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict 1.7.2 Wiring terminals supplying Class 2 outputs marked with voltage rating and "Class 2" or equivalent N/A 1.7.6 Special fuse replacement marking for operator accessible fuses N/A 1.7.6 Lamp replacement information indicated on lampholder in operator access area N/A 1.7.7 Identification of terminal connection of the equipment earthing conductor N/A 2.1.
Issue Date: 2003-09-25 Page 19 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict 2.6 Units having receptacles for output a.c. power connectors which are generated from an internal separately derived source have the grounded circuit conductor suitably bonded to earth N/A 2.6.3.3 Capacity of connection between earthing terminal and parts required to be earthed subject to special conditions based on the current rating of the circuit N/A 2.6.3.
Issue Date: 2003-09-25 Page 20 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict 3.2.1 Class II equipment provided with 15 or 20 A standard supply outlets, Edison-base lampholders or single pole disconnect device provided with a polarized type attachment plug N/A 3.2.3 Permanently connected equipment has provision for connecting and securing a field wiring system (i.e. conduit, or leads etc.) per the NEC and CEC, Part 1 N/A 3.2.
Issue Date: 2003-09-25 Page 21 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict 3.3.1 Terminals for the connection of neutral conductor identified by a distinctive white marking or other equally effective means N/A 3.3.3 Wire binding screw terminal permitted for connection of No. 10 AWG (5.3 mm²) or smaller conductor if provided with upturned lugs, cupped washer or equivalent retention N/A 3.3.
Issue Date: 2003-09-25 Page 22 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict 3.6 Equipment with earthed terminal (terminal for the grounded conductor) of power source connected to frame of the unit provided with special instructions and provision for earthing N/A 3.
Issue Date: 2003-09-25 Page 23 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict 4.7.1 Automated information storage equipment intended to contain more than 0.76 mm³ of combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system N/A 4.7.
Issue Date: 2003-09-25 Page 24 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test Result - Remark Verdict 6.2.1 Special requirements for enameled wiring used as electrical separation provided between parts connected to telecommunication network and telecommunication circuitry intentionally isolated from network N/A 6.2.1 Digital line termination equipment (e.g., NCTE) subject to separation requirements. N/A 6.
Issue Date: 2003-09-25 Page 25 of 25 Report Reference # E203413-A17-CB-1 IEC 60950 SubClause Difference + Test M.
Issue Date: 2003-09-25 Page 1 Report Reference # Enclosure Photographs (Total 6 Pages including this Cover Page) Supplement Id Description 3-01 Top View 3-02 Bottom View with US/Canada and Japan plug 3-03 Interior View 3-04 Interior view with insulation sheet and shield 3-05 Interior bottom view 3-06 Bottom view with euro plug UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 2 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 3 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 4 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 5 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 6 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 7 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 1 Report Reference # Enclosure Diagrams (Total 6 Pages including this Cover Page) Supplement Id Description 4-01 Transformer (T1) 4-02 Insulation sheet and Shield UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 2 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 3 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 4 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 5 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 6 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 1 Report Reference # Enclosure Schematics + PWB (Total 8 Pages including this Cover Page) Supplement Id Description 5-01 PWB layout UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 2 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 3 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 4 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 5 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 6 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 7 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 8 Report Reference # UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 1 Report Reference # Enclosure Miscellaneous (Total 2 Pages including this Cover Page) Supplement Id 7-01 Description Label UL International Demko A/S E203413-A17-CB-1
Issue Date: 2003-09-25 Page 2 Report Reference # UL International Demko A/S E203413-A17-CB-1