Operating instructions

Issue Date: 2003-09-25 Page 35 of 42 Report Reference #
E203413 -A17-CB-1
IEC 60950
Clause Requirement + Test Result - Remark Verdict
TRF No.: 1950__F UL International Demko A/S TRF originator: FIMKO
05-2
Transformer -
Core
-- -- Toroidal core,
ferrite, 9.3 mm
OD by 4.8 mm
ID by 1.3 mm
thick
-- --, --
05-3.
Transformer -
Tubing
Fluo Tech
Industries Co.,
Ltd.
TFL Minimum 200
degree C, 150 V,
Provided on the
end lead of coil.
UL224 UL, --
05-4.
Transformer -
Glue
Dow Corning
Corp.
3165 V-2 minimum,
Provide on the
bottom of
transformer.
UL94 UL, --
05-5.
Transformer -
Heat shrink
Tubing
-- -- FEP, PTFE,
PVC, TFE,
neoprene,
polyimide or
marked VW -1;
105 degree C,
300 V
UL224 UL, --
06. Power
Module
Universal
Microelectronics
Co., Ltd.
UP0051A-05 I/P: 100-240Vac,
47-63Hz, 0.2A
maximum; O/P:
5Vdc, 1A
UL60950,
IEC60950: 1999
UL, TUV CB Cert
No. JPTUV-
006434
07. Insulator Formex, Div Of
Illinois Tool
Works Inc,
Formerly
FORMEX GK V-0 minimum,
115 degree C.
Overall see
Enclosure
diagram 4-02 for
detail dimension,
minimum 0.41
mm, located
between power
module and
shielding.
UL94, UL746C UL, --
08. Shielding -- -- Metal, overall
see Enclosure
diagram 4-02 for
detail dimension.
-- --, --
09. Enclosure GE Plastics
Pacifics
945 V-0, 80 degree
C, overall 112.6
by 63.6 by 44.0
mm, minimum
2.0 mm thick.
UL94, UL746C UL, --
10. Connector -- -- SELV, RJ-45,
one provided
-- --, --