Clause Requirement + Test Result - Remark Verdict
TRF No.: 1950__F UL International Demko A/S TRF originator: FIMKO
1.6.2 TABLE: electrical data (in normal conditions) Pass
fuse # I rated (A) U (V) P (W) I (mA) I fuse (mA)
condition/status
-- -- 90/47Hz 3.0 60 -- Maximum normal load
-- -- 90/63Hz 3.1 60 -- Maximum normal load
-- 0.1 100/47Hz 2.9 54 -- Maximum normal load
-- 0.1 100/63Hz 2.9 54 -- Maximum normal load
-- 0.1 240/47Hz 2.5 29 -- Maximum normal load
-- 0.1 240/47Hz 2. 4 30 -- Maximum normal load
-- -- 254/47Hz 2.8 29 -- Maximum normal load
-- -- 254/63Hz 2.6 30 -- Maximum normal load
supplementary information:
Maximum normal load: Connect to computer and transmit data continuously.
2.10.3 and
2.10.4
TABLE: clearance and creepage distance measurements Pass
clearance cl and creepage
distance dcr at/of:
Up
(V)
U r.m.s. (V)
required cl
(mm)
cl (mm) required
dcr (mm)
dcr
(mm)
CN1 (power module) to
shielding
<448 <250 4.2 >5.0 5.0 >5.0
F1 (power module) to shielding
<448 <250 4.2 >5.0 5.0 >5.0
J1 to U4 pin1 <448 <250 4.2 >5.0 5.0 >5.0
Under T1 <420 <250 4.0 >5.0 5.0 >5.0
supplementary information:
--
2.10.5 TABLE: distance through insulation measurements Pass
distance through insulation di at/of: U r.m.s.
(V)
test voltage (V)
required di
(mm)
di
(mm)
Insulation sheet 240 3000 0.4 >0.41
Enclosure 240 3000 0.4 >2