Operating instructions
Issue Date: 2003-09-25 Page 39 of 42 Report Reference #
E203413-A17-CB-1
IEC 60950
Clause Requirement + Test Result - Remark Verdict
TRF No.: 1950__F UL International Demko A/S TRF originator: FIMKO
4.5.2 TABLE: ball pressure test of thermoplastics Pass
allowed impression diameter (mm)..................... :
2 mm
—
part test temperature (°C)
impression diameter
(mm)
Enclosure, GE Plastics/945, 2.4 mm 125 1
supplementary information:
--
5.2 TABLE: electric strength tests and impulse tests Pass
test voltage applied between: test voltage (V) breakdown
Yes / No
Primary to SELV 4242 Vdc No
Primary to Enclosure with foil 4242 Vdc No
T1 primary winding to SELV winding 3000 Vac No
T1 primary winding to core 3000 Vac No
T1 SELV winding to core 3000 Vac No
supplementary information:
--
5.3 TABLE: fault condition tests Pass
ambient temperature (°C) .................................. :
See below
—
model/type of power supply............................... :
--
—
manufacturer of power supply............................ :
--
—
rated markings of power supply ......................... :
--
component
No.
fault test voltage
(V)
test time fuse
No.
fuse current
(A)
result
C25 Short 240 Vac
< 1S
-- 0.03 - 0 Breaker open, NB, NC, NT.
T1 (B1-B2) Short 240 Vac 2 hrs -- 0.03 NO, NB, NC, NT, CT.
Maximum temperature T1
coil: 58 degree C, Ambient:
25.7 degree C.
T1 (G1-G2)
Short 240 Vac 2 hrs -- 0.03 NO, NB, NC, NT, CT.
Maximum temperature T1
coil: 51.3 degree C,
Ambient: 25.8 degree C.
RJ45 Pin1-
8 to ground
Overload 240 Vac 1 min -- 0.03 NO, NB, NC, NT. Open
circuit voltage measured 0
V.