Issue Date: 2003-09-25 Page 3 of 25 Report Reference #
E203413-A17-CB-1
IEC 60950
SubClause
Difference + Test Result - Remark Verdict
UL International Demko A/S
3.2.1 Supply cord of single-phase equipment having a
rated current not exceeding 10 A shall be provided
with a plug according to the Heavy Current
Regulations, Section 107 -2-D1.
Class I equipment provided with socket-
outlets with
earth contact or which are intended to be used in
locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase
equipment having a rated current exceeding 10 A
is provided with a supply cord with a plug, this plug
shall be in accordance with the Heavy Current
Regulations, Section 107 -1-D1 or EN 60309-2.
N/A
Finland - Differences to IEC60950, Third Edition (1999)
6.1.2.2 The exclusions are applicable for PERMANENTLY
CONNECTED EQUIPMENT and PLUGGABLE -
EQUIPMENT TYPE B only.
N/A