Operating instructions

Issue Date: 2003-09-25 Page 7 of 25 Report Reference #
E203413-A17-CB-1
IEC 60950
SubClause
Difference + Test Result - Remark Verdict
UL International Demko A/S
3.2.5 In table 3B, replace the first four lines by the
following:
Up to and including 6 0.75 1)
Over 6 up to and including 10 0.75 2) 1.0
Over 10 up to and including 16 1.0 3) 0.5
In the Conditions applicable to table 3B delete the
words "in some countries" in condition 1.
In NOTE 1, delete the second sentence.
N/A
3.3.4 In table 3D, delete the fourth line - conductor sizes
for 10 to 13 A. and replace with the following:
Over 10 up to & including 16
1.5 to 2.5 1.5 to by 4.
Delete the fifth line - conductor sizes for 13 to 16A.
N/A
4.3.13 Replace the second compliance paragraph by:
For equipment using LEDs or lasers, compliance is
checked according to EN 60825- 1
N/A
4.3.13 NOTE 1 - if equipment falling within the scope of
EN 60950 is inherently a class 1 laser product, i.e.
it contains no embedded laser or LED of a higher
class number, then a laser warning label or other
laser warning statement is not required (see 1.1 of
EN 60825-1).
Renumber the NOTE below the third compliance
paragraph as NOTE 2
N/A
H Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA the dose rate shall
not exceed 1µSv/h (0.1 mR/h) (see note). Account
is taken of the background level.
Replace the NOTE as follows:
NOTE - These values appear in directive
96/29/Euratorm.
N/A
P Replace the text of this annex by:
See annex ZA
Pass