Issue Date: 2003-09-25 Page 11 of 25 Report Reference #
E203413-A17-CB-1
IEC 60950
SubClause
Difference + Test Result - Remark Verdict
UL International Demko A/S
Annex A Add the subclause A.101titled:
"Flammability tests for classifying materials VTM"
and the following:
"Thin sheet materials shall comply with ISO 9773"
N/A
Annex G Add to the Note for Table G.1.
"2. In Japan, MAINS TRANSIENT VOLTAGE for
equipment with a Nominal AC MAINS SUPPLY
VOLTAGE of 100V is to be decided based on the
column where Nominal AC MAINS SUPPLY
VOLTAGE in Table G.1 is 150V"
N/A
Annex P Add:
"IEC 61965:2000, Mechanical Safety for Cathode
Ray Tubes"
N/A
Annex U Replace 2nd paragraph as follows:
"This annex covers to round winding wires having
diameters between 0.05 mm and 5.00 mm"
N/A
U.2.1 Replacement:Electric strength
"The test sample is prepared per IEC 60851-
5:1997, 4.4.1 (for a twisted pair and subjected to
the test of 5.2.2, with a test voltage not less than
twice the appropriate voltage in table 5B (see
5.2.2) of this standard. However, the minimum
values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V, or;
- for REINFORCED INSULATION, 6000 V"
N/A
U.2.2 Replacement:Flexibility and adherence
Test 8 of IEC 60851-3:1996, 5.1.1, using the
mandrel diameter of Table U.1 (mm)
N/A
U.2.2 Test voltage not less than twice the appropriate
voltage in table 5B (see 5.2.2) of this standard and
not less than:
- 1500 V for BASIC INSULATION or
SUPPLEMENTARY INSULATION, or;
- 3000 V for REINFORCED INSULATION
N/A