Operating instructions
Issue Date: 2003-09-25 Page 21 of 25 Report Reference #
E203413-A17-CB-1
IEC 60950
SubClause
Difference + Test Result - Remark Verdict
UL International Demko A/S
3.3.1 Terminals for the connection of neutral conductor
identified by a distinctive white marking or other
equally effective means
N/A
3.3.3 Wire binding screw terminal permitted for
connection of No. 10 AWG (5.3 mm²) or smaller
conductor if provided with upturned lugs, cupped
washer or equivalent retention
N/A
3.3.4 Terminals suitable to accept wire sizes (gauge)
used in the U.S. and Canada
N/A
3.3.4 Terminals accept current -carrying conductors rated
125% of the equipment current rating
N/A
3.3.6 Field wiring terminals marked to indicate the
material(s) of the conductor appropriate for the
terminals used
N/A
3.3.6 Connection of an aluminum conductor not
permitted to terminal for equipment earthing
conductor
N/A
3.3.6 Field wiring connections made through the use of
suitable pressure connectors (including set screw
type), solder lugs or splices to flexible leads
N/A
3.3.8 Connectors and field wiring terminals involving
external Class 2 or Class 3 circuits provided with
marking indicating minimum Class of wiring to be
used
N/A
3.3.8 Marking located adjacent to terminals and visible
during wiring
N/A
3.4.2 Separate motor control device(s) required for cord-
connected equipment rated more than 12 A, or with
motor rated more than 1/3 hp or more than 120 V
N/A
3.4.8 Vertically mounted disconnect devices, oriented so
up position of handle is "on"
N/A
3.4.10 For computer-room applications, equipment with
battery systems capable of supplying 750 VA for 5
min require battery disconnect means
N/A
3.6 Connections to a centralized DC power system
comply with requirements for branch circuits in
Sub-clause 3.2
N/A
3.6 Earthing of d.c. powered equipment provided
N/A
3.6 Overcurrent and earth fault protection in
accordance with 2.7 either provided in equipment
or as part of building installation
N/A