Operating instructions

Issue Date: 2003-09-25 Page 23 of 25 Report Reference #
E203413-A17-CB-1
IEC 60950
SubClause
Difference + Test Result - Remark Verdict
UL International Demko A/S
4.7.1
to contain more than 0.76 mm³ of combustible
a gaseous agent extinguishing system
N/A
4.7.3
than ducts or plenums provided with metal
enclosure or with non-metallic enclosure having
adequate fire-resistance and low smoke producing
characteristics
N/A
4.7.3 Low smoke-producing characteristics evaluated
according to UL 2043
N/A
4.7.3 Equipment for installation in space used for
environmental air as described in Sec. 300-22(c) of
the NEC provided with instructions indicating
suitability for installation in such locations
N/A
4.7.3.1 Flame spread rating for external surface of
combustible material with exposed area greater
m; 50 or less for computer room applications or
200 or less for other applications
N/A
4.7.3.4
Wire marked "VW-1" or "FT-1" considered
equivalent
VW-1 or FT-1 cord used. Pass
5.1.8.1.1 Touch current due to ringing voltage for equipment
containing telecommunication network leads
N/A
5.1.8.2 When multiple ports receive ringing voltage,
simulated ringing applied to 3 % if ports in excess
of 3
N/A
5.1.8.2 Special earthing provisions and instructions for
equipment with high touch current due to
telecommunication network connections
N/A
5.3.6 Overloading of SELV connectors and print
ed wiring
board receptacles accessible to the operator
See appended table 5.3. Pass
5.3.6 Tests interrupted by opening of a component
repeated two additional times
N/A
5.3.8.1 Test interrupted by opening of wire or trace
continued by shorting gap
N/A
6 Specialized instructions, as appropriate, provided
for equipment which may be connected to a
telecommunications network
N/A
6 Marking identifying function of telecommunication
type connectors not used for connection to a
telecommunication network
N/A