The power redundancy options are shown in Figure 5-11. We clicked Change
(next to Power Redundancy with Compute Node Throttling Policy) to show the
power redundancy options.
Figure 5-11 Changing the redundancy
5.6.5 Power limiting and capping policies
Simple power capping policies can be set to limit the amount of power consumed
by the chassis. Two policy options are available, which you can configure with
the Chassis Management Module:
򐂰 No Power Capping: The maximum input power is determined by the active
Power Redundancy policy.
򐂰 Static Capping: Sets an overall chassis limit on the maximum input power. In
a situation where powering on a component could cause the limit to be
exceeded, the component cannot power on. No capping is the default. Static
capping can be set as a percentage, starting with a minimum value. If there is
insufficient power available to power on a compute node, the compute node
does not come online.