210 IBM Flex System p260 and p460 Planning and Implementation Guide
8. Network topology options include separate networks for management and
data, or a single network for both data and management traffic from the
chassis. The preferred practice is to have separate management and data
networks. To simplify this example, a combined network is configured, using
the topology on the right side of Figure 6-51.
Figure 6-51 FSM network topology options
Click Next to continue to the actual network configuration.
9. The LAN adapter configuration is shown in Figure 6-52 on page 211. There
are two adapters listed. The first is from the FSM management network
adapter, which allows FSM to communicate on the chassis management
network. Traffic from this adapter flows through the Chassis Management
Module and uses the CMM physical connection to the network.