296 IBM Flex System p260 and p460 Planning and Implementation Guide
No memory or processing resources are committed. In this step, and in the
rest of the steps for defining the virtual server, we are defining only the
resources that are allocated to this virtual server after it is activated.
3. Click Next to move to the virtual adapter definitions.
Virtual Ethernet
In this task, the process is repeated for each virtual adapter to be defined on the
VIOS, but the characteristics differ with each adapter type. The order in which
the adapters are created does not matter.
Be sure to double-check your planning documentation to ensure that you are
specifying the correct VLAN IDs for the virtual Ethernet adapters, that the virtual
SCSI client and server adapters are correctly linked, and that the WWPN of the
virtual Fibre Channel adapters are noted and provided to the SAN
administrators.
If you performed the steps in “Memory and processor settings” on page 294, you
should see the window shown in Figure 7-10.
Figure 7-10 Create the bridging virtual Ethernet adapter in the VIOS