User`s manual
En-22
MS-7672 Mainboard
English
MS-7672 Mainboard
English
Voltage Check Point: FV1
This voltage check point set is used to measure the current CPU core/ CPU IO/ CPU_
SA/ DDR/ PCH voltage.
CPU core voltage: measure the current CPU
core voltage with VCCP point and GND point by
using a multimeter.
CPU_VTT voltage: measure the current CPU
I/O voltage with CPU_VTT point and GND point
by using a multimeter.
DDR voltage: measure the current DDR voltage
with VCC_DDR point and GND point by using a
multimeter.
PCH voltage: measure the current PCH voltage
with PCH_1P05 point and GND point by using a
multimeter.
VCC_DDR
GND
GND
1
7
PCH_1P05CPU_SA
CPU_VTT
VCCP
GND
1
7
VCCP
GND
1
7
CPU_VTT
GND
1
7
CPU_SA
GND
1
7
VCC_DDR
GND
1
7
PCH_1P05
CPU_SA voltage: measure the current CPU_SA
voltage with CPU_SA point and GND point by
using a multimeter.