GS 001 Owner’s Manual & Warranty B100 B110 B130 B140 B150 Alpine Blue Sea Camaro Elegance Super Camaro DO NOT RETURN MERCHANDISE DIRECTLY TO YOUR ORIGINAL SELLING STORE. CALL MSPA AFTER SALES SERVICE CENTER FOR ANY PRODUCT QUESTIONS. CONTACT US AT info@the-mspa.com www.the-mspa.
IMPORTANT SAFETY INSTRUCTIONS ! WARNING For your own safety and that of your equipment, make sure to take the following precautions. Failure to follow warning notices and instruction may result in property damage, serious injury or death.
WARNING: DO NOT turn on the spa tub when the water is frozen. WARNING: Use only approved spa tub accessories. Use of improper or non-approved accessory will void the manufacturer’s warranty. WARNING: RISK OF ELECTRIC SHOCK - Install at least 1.5m (5 feet) from all metal surfaces. WARNING: RISK OF ELECTRIC SHOCK - Never operate any electrical appliances when the spa tub is in use or when your body is wet. Never place any electric appliance, such as a light, telephone, radio, or television, within 1.
PURCHASE INFORMATION Bubble SPA (GS) Style No. (color) B- 00B Dark Grey� B- 0A Blue B- 30 Black B- 40B Grey B- 50 Black Item No. A08 080 A08 08 A08 083 A08 073 A08 075 Pool Shape Oval Seating Capacity Water Capacity 700 Ltr/ 85 gal. Round Round Round Round 4 4 4 4-6 800 Ltr/ gal. 800 Ltr/ gal. 800 Ltr/ gal. 00 Ltr/3 0 gal. Type Above ground spa Above ground spa Above ground spa Above ground spa Above ground spa 0 kgs/44 lbs. dry; 7 0 kgs/ 584 lbs.
INSTRUCTIONS NOTE: Ensure to check all parts are present. A: Aluminium foil top lid and zipper 1pc B: Control panel 1set C: Spa pool 1pc D: Temp barrier mat (optional) 1pc E: Digital lock 1pc F: Inflation Hose 1pc G: Filter cartridge 2pcs H: Drainage hose 1pc I: Repair kit 1set J: Manometer 1pc K: Inflatable bladder (optional) 1pc L: Nail to fix the control box 2pc L. A. Site Requirements WARNING: The floor has to be capable of supporting the expected load of the spa tub.
B. Assembly Required number of personal for assembly: Spa tub installation requires a licensed electrician and an ordinary installation individual. 2 The connecting cable must be above H07RN-F 1.0mm ) ) 3) terminal box 1) Use a screwdriver to take the terminal box out from the control box, and then open the cover of the terminal box. 2) Connect the wire to the terminal box according to the mark of the lines. Make sure the wires are well fastened.
d) Connect the pin plugs. Make sure that plugs are properly matched together, screw a cap, and then you’ ll see yellow light on control panel, no bent or wet for the pin inside male connector which will cause failure connection. e) Open the air valve under the control panel. Screw one end of inflation hose onto it. f) Unscrew the top part of air valve on the Spa. Screw the other end of inflation hose onto Manometer, and then put into the air valve.
j) Fill the Spa Using a garden hose to fill the Spa until it reaches the area between two water lines printed inside the Spa wall. WARNING: 1. Fill in water carefully especially for the first time of use. Water level must reach the minimum water line but not exceed the maximum water line, otherwise it may cause pump failure. 2. Please avoid water spillage which will cause damage to the electric parts. 3. After filling in water, please check air pressure again and make sure the pin reads in green sector.
POWER PACK OPERATION Warning: to avoid function failure and damage, please do not operate until spa is filled with water to the minimum water mark. It is the owner’s responsibility to make sure the installation conditions are met and the following safety and warning rules are exercised. Any failure and damage which result from dry-run, water spillage, excessive humidity, or structural loading will void the warranty.
Function Failure Alarm on the Control Panel When power pack doesn’t work properly, there will be corresponding error code displayed on the control panel in time: Please check details from troubleshooting page. Maintaining Spa Water Poor water quality can be extremely hazardous to your health. We recommend you do following things: A: Please use filter cartridge. Screw the filter onto the water inlet on the spa wall by turning it clockwise.
Special Notice on Water Treatment Please read about water quality and filter in user manual. Always shower before you enter your MSpa! Please use test strip to test your water chemistry before each use of the spa, no less than once per week. The pH level must be between 7.2 and 7.8, total alkalinity between 80 and 120ppm and free chlorine between 3 to 5ppm. Too low of a pH level will result in excessive wrinkles and damage to the spa pool as well as corrosion in the motor unit.
2. Consumers should keep the screws and other small parts during dismantling the filter pump. Any damage or missing parts caused by improper operation will void your warranty. Make sure all water is drained from the spa tub and the control box. This is essential to extend the life of the spa. You could also use a vacuum or hair blower to suck up or blow out the water from the pipe and pump lines. Filter cartridge also needs to be removed. It is recommended to store the spa tub in the original packaging box.
Error code "HEF”,“BB F”, “FEF” in the display Error code “SPL” & "SPH" in the display Please cut the power supply off to your Mspa, and then plug in again, make sure the right connection of pin plugs, restart power pack operation. If it still doesn’t work, please contact your country MSpa service center. Pin plug connection failure Please cut the power supply off to your Mspa, and then plug in again, make sure the right connection of pin plugs, restart power pack operation.
MSpa® products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. Oriental Recreational Products (Shanghai) Co., Ltd. (ORPC) is pleased to extend this limited warranty coverage to the original purchaser of an MSpa® Product. This warranty is not transferable. The warranty period commences on the original purchase date through 6-12 months accordingly.
Damages caused by or attributable to the following incidents are specially excluded: a. Any damage caused by the operation of the spa with water temperatures outside the range of 0°C-42° C/32°F-107.6°F (Europe/Australia) or 0°C-40°C/32°F-104°F (USA) b. Any damage caused by clogged, dirty or calcified filters c. Any damage that are purely aesthetic and do not hinder the function of the MSpa d.
After Sales Service Center Address Germany ORPC GmbH Braunstrasse 1 24145 Kiel Germany Tel.: + 49 ( 0 ) 431- 66 95 26 9-0 Fax: + 49 ( 0 ) 431- 66 95 26 9-98 E-mail: service@orpcgmbh.de Website: www.orpcgmbh.