Owner`s manual
13
Error code
"HEF”,“BB
F”, “FEF” in
the display
Error code
“SPL” &
"SPH" in
the display
Please cut the power supply off to your Mspa, and then plug in again, make sure the right connection of pin
plugs, restart power pack operation. If it still doesn’t work, please contact your country MSpa service center.
Please cut the power supply off to your Mspa, and then plug in again, make sure the right connection of pin
plugs, restart power pack operation.
Please check if there is any water frozen inside the spa and control box, use warm water to melt and get
water temperature higher than zero degree.
Do not use the spa. Please contact your country MSpa service center.
Pin plug connection failure
SPL, temperature lower than
zero degree
SPH, abnormal high
temperature
Warning: Water protection levels of Appliance
at different product zones are different see the
following scheme.
NOTE - The measured zone dimensions are
limited by walls and fi xed partitions.
Figure 702A - Zone dimensions of swimming
pools and paddling pools.
SAFETY & ANNOUNCEMENTS
a. A local supplementary equipotent bonding
shall connect all extraneous conductive parts in
Zones 0,1 and 2 with protective conductors of all
exposed conductive parts situated in these zones.
b. The measures of protection by non-conducting location and by earth-free equipotent bonding are not
permitted.
c. Electrical equipment shall have at least the following degrees of protection:
In Zone 0: IPX8 In Zone 1: IPX5 In Zone 2: IPX4.
d. Junction boxes shall not be installed in Zones 0 and 1 except in zone 1,where permitted for SELV
circuits.
e. In Zones 0 and 1, no switchgear and accessories shall be installed.
f. The transformer must be located outside zone1.
1.5m
Zone 1 Zone 1Zone 2 Zone 2
Zone 0
Zone 0
Zone 0
1.5m 1.5m2.0m2.0m
2.5m
2.5m
1.5m
WATER PROTECTION LEVEL