Operator`s manual
AugerControl F %
Priortooperatingyoursnowthrower,carefullyreadandfollowall
instructionsbelow.Performalladjustmentstoverifyyoursnowthroweris
operatingsafelyandproperly.
Checktheadjustmentoftheaugercontrolasfollows:
1. Theaugercontrolislocatedontheleft handle.SeeFigure14inset.When
theaugercontrolisreleasedandinthedisengaged"up"position,thecable
shouldhaveverylittle slack.ItshouldNOTbetight.
2. Ina well-ventilatedarea,start thesnowthrowerengine.Referto Starting
theEngineintheOperationsection.
3. Whilestandingintheoperator'sposition(behindthesnowthrower),engage
theauger.
4. Allowtheaugerto remainengagedfor approximatelyten(10)seconds
beforereleasingtheaugercontrol.Repeatthisseveraltimes.
5. Withtheaugercontrolin thedisengaged"up" position,walkto thefrontof
themachine.
6. Confirmthat theaugerhascompletelystoppedrotatingandshowsNOsigns
of motion.IftheaugershowsANYsignsof rotating,immediatelyreturnto
theoperator'spositionandshutoff theengine.WaitforALLmovingpartsto
stopbeforeadjustingtheaugercontrol.
7. Toreadjustthecontrolcable,loosenthe upperhexboltontheaugercable
bracket.SeeFigure14.
8. Positionthebracketupwardto providemoreslack(ordownwardto increase
cabletension).
9. Retlghtentheupperhexbolt.
J \
/
\
/_ Auger Control
Figure14
J
10. Repeatsteps2-6abovetoverifyproperadjustmenthasbeenachieved.
13