Manual

SECTION5: ADJUSTINGYOURLOGSPLITTER
Hex
Bolts
Adj
Bolts
WARNING: Do not at any time make any
adjustments without first stopping engine,
disconnecting spark plug wire, and
grounding it against the engine.
Attached
To Cylinder_.,.._
Plate
Plate
Figure 9
WedgePlateAdjustment
As normal wear occurs, adjust the boltson the side of
the wedge plate to eliminate the excess space between
the wedge plate and beam. See Figure 9.
Loosen thejam nuts on the two adjustment bolts on
the side of the gib plate. Turn the adjustment bolts
in until snug and then back them off slowly until the
wedge assembly willslide on the beam.
Tighten the jam nuts securely against the gib plate
to hold the adjustment bolts inthis position.
GibPlateAdjustment
Periodically remove and replace the "gibs" (spacers)
between the wedge plate and the back plate.
See Figure 9.
NOTE: The gibs may be rotated and/or turned over for
even wear.
Remove the center bolt on top of the wedge plate.
Slide the gib plate out.
Remove and replace the gibs.
Reassemble the gib plate, making certain flat
washers are in place under the gib plate.
Readjust the bolts on the side of the wedge plate.
SECTION6: MAINTAININGYOURLOG
WARNING: Before cleaning, lubricating,
repairing, or inspecting, disengage the
control lever and stop engine. Disconnect
the spark plug wire and ground it against
the engine to prevent unintended starting.
ReservoirFluid
Check the hydraulic fluid level in the log splitter
reservoir tank before each use. Maintain fluid level
within 3" to 3 1/2" from top at all times. Change the
hydraulic fluid in the reservoir every 100 hours of
operation. Disconnect the suction hose from the bottom
of the reservoir tank and drain the fluid into a suitable
container. Refill using only Dexron III automatic
transmission fluid or 10W AW hydraulic fluid.
Be aware of the environment when disposing of
used petroleum products. Please dispose of used
hydraulic fluid and engine oil at approved recycling
centers.
WARNING: Use extreme caution when
working with kerosene, it is flammable
fluid. Extinguish cigarettes, cigars, pipes,
and other sources of ignition.
SPLITTER
HydraulicFilter
Change the hydraulic filter every 50 hours of operation.
Use only a 10 micron hydraulic filter. Order part number
723-0405.
BeamAndSplittingWedge
Lubricate both sides of the beam (where it comes into
contact with the splitting wedge) before each use with
engine oil. The wedge plate on the log splitter is
designed so the gibs on the side of the wedge plate can
be removed and rotated and!or turned over for even
wear.Make certain to readjust the adjustment bolts so
wedge moves freely, but no excess space exists
between the wedge plate and beam.
HoseClamps
Check the hose clamps on the suction hose (attached
to side of the pump) for proper tightness before each
use. Check the hose clamps on the return hose at least
once a season.
10