A06 FORM NOK=769-01847 jqa=mêçÇìÅíë=^âíáÉåÖÉëÉääëÅÜ~Ñí=√=p~~êÄêΩÅâÉå=√=dÉêã~åó
English Information on the rating plate This information is very important for subsequent identification when ordering spare parts and for customer service. Enter all information on the rating plate of your unit in the following field. Safe operating practices Using the unit correctly This wood splitter is designed to be used – for splitting firewood for private use – in accordance with the descriptions and safety instructions indicated in this operating manual. Any other use is not as intended.
English Before detecting leaks, put on goggles and protective gloves and then move a piece of cardboard or wood over the suspected area and ascertain whether the cardboard or wood has changed colour. If escaping liquid causes injury, immediately cause a doctor. Serious inflammation or reactions may occur if medical treatment is not implemented immediately. To ensure a secure footing / safe working environment, always keep the work area and the area around the unit free of objects.
English Operating Manual for Wood Splitter • Tighten the castellated nut until it is tight, then slacken it by approx. 1 /3 revolution and until one of the slots in the nut is facing the hole in the axle. • On both wheels insert a cotter pin through the slot in the nut and through the hole in the axle and secure by bending out the ends. Note: The wheels should rotate freely and there should be no lateral play. Place the caps on the hubs and tap into place with a rubber mallet.
English Operating Manual for Wood Splitter 3 • 4 2 Unscrew the support (10) from the splitting column, on the side of the control valve. Fig. 8 9 8 1 • Re-attach support (10) to the control valve side of the splitting column, aligning the ends of the support with the column flanges. See Fig. 9b. 5 5 6 7 10 Fig.5 1 2 3 4 5 6 7 Filter head Hose clip Control valve Connected to the cylinder Return-flow hose Filter To the hydraulic tank 7 Fig.8 Assembly work on the splitting column Figs.
English Operating Manual for Wood Splitter • Unit Lubricating the splitting column Lubricate the area of the splitting column (where the splitting wedge moves to and from) with engine oil; do not use lubricating grease. Filling the hydraulic tank Fig. 10 1 2 Fig.10 The tank has a capacity of 13.2 l. • Screw the vented dipstick (1) out of the inlet nozzle opening in the hydraulic tank (2). • Fill the hydraulic tank with Dexron III automatic gear oil or 10W AW hydraulic fluid.
English Operating Manual for Wood Splitter Controls Fig. 11 Caution Compare the diagram in Fig. 11 with the controls on your unit and familiarise yourself with their functions before you start work. In an emergency you must know how to switch off the unit quickly. 4 A 5 6 12 6 7 B 8 9 A 13 2 B 3 1 10 11 14 15 F ig .
English Operating the unit Also follow the instructions in the engine manual! Danger Risk of injury. Persons, children and/or animals must be kept away from the unit while it is being operated. They could be injured by ejected objects, etc. Children must never operate the unit. Always secure the unit to prevent it from rolling away. When working on slopes, the unit may tip over and you may be injured. Therefore be especially careful if working in this situation.
English Splitting wood with the unit Caution Follow all safety instructions when operating the unit. Always secure the unit to prevent if from rolling away. The pieces of wood which are to be split must not exceed or fall below the following dimensions: Maximum length: 700 mm Minimum length: 150 mm Maximum diameter: 500 mm Minimum diameter: 100 mm Always split pieces of wood along the wood grain.
English Before carrying out any work on this unit • Switch off the engine. • Move the operating lever to Neutral. • Wait until all moving parts have come to a standstill; leave the engine to cool down. • Remove spark-plug terminal from the engine to prevent the engine from starting unintentionally. • Before repairing, adjusting or checking hoses, hose connections, pipelines or other components, depressurise the hydraulics. Cleaning Caution Risk of damaging the unit.
English The complete unit with engine Once per season have a repair shop inspect and service the unit. Also follow the instructions in the engine manual concerning maintenance of the engine. Shutting down the unit Caution Material damage to the unit. When the engine has cooled down, store the unit in a clean and dry location. If storage is prolonged, always protect the unit, e.g. in winter, from rust. After the season or if the unit is not used for more than a month: • Clean the unit.
English Operating Manual for Wood Splitter Troubleshooting the engine Problem Engine does not start Engine is misfiring Engine is overheating Cause Solution Ignition cable removed. Tank empty or fuel stale. Throttle/engine operating switch not in start position. Choke not actuated Spark plug defective. Spark-plug terminal is loose. Choke still actuated. Fuel line blocked or petrol stale. Air filter dirty. Carburettor misaligned. Too little engine oil. Air filter dirty. Carburettor incorrectly set.