Specifications

KITCHEN HOOD DETAIL
SUPPLY AIR BLOWER
EXHAUST FAN PER
NFPA 96
MASTER ELECTRICAL PANEL
REMOVABLE GREASE TROUGH
AND REMOVABLE GREASE CUP.
•" HANGER RODS w/ TURNBUCKLES
BY INSTALLING CONTRACTOR.
CEILING
MAKE-UP AIR SUPPLY DUCT
ACCESS DOOR PER NFPA-96
M.V.D.
SUPPLY COLLAR WITH U.L. LISTED
FIRE DAMPER.
40" AFF (MIN.)
SUPPLY AIR
DEFLECTION LOUVERS.
(VERIFY IF REQUIRED)
EXTRACTOR TYPE GREASE FILTERS.
COMPONENT HARDWARE (ALUMINUM).
U.L. CLASSIFIED w/ LIFT HANDLES.
PER NFPA 96
C7
SCALE:
NONE
SURFACE MOUNTED CONTROL PANEL
(115V.) STAINLESS STEEL PANEL
WITH ONE TOGGLE SWITCH & SIGNAL
FANS ONE TOGGLE SWITCH & SIGNAL
LIGHT FOR EXHAUST & SUPPLY AIR
SWITCH FOR CANOPY LIGHTS (115V.)
LIGHT FOR PREHEAT. ONE TOGGLE
REQUIRED WITH GLOBES AND GUARDS.
(115V.) U.L. LISTED TEN LIGHTS
VAPOR PROOF INCANDESCENT LIGHTS
SWITCH
DISCONNECT
INLET DAMPER
MOTORIZED
UNIT
MAKE-UP AIR
FILTERS
INDUSTRIAL
SUPPORTS
ADJUSTABLE
10'-0" (MIN)
FIRE DAMPER
STEEL CLOSURE
STAINLESS
18 GAUGE
GND
GND
GND
W1,T1,TYPE,T2,W2,REF,SH,SHDWGNAM,FILENAME,FULLFILENAME
MC,MC,MC,MC,MC,MC,MC,MC,L,L
0.000000,0.031250,0.000000
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Demand Control Ventilation, w/ 2 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans modulate
based on duct temperature. INVERTER DUTY THREE PHASE MOTOR REQUIRED! Room temperature sensor shipped loose
for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds 50 feet.
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Demand Control Ventilation, w/ 2 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans modulate
based on duct temperature. INVERTER DUTY THREE PHASE MOTOR REQUIRED! Room temperature sensor shipped loose
for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds 50 feet.
WH
BK
BK
BK
BK
WH/BL
BL
A
B C
D
E
F
G H
I
1
2
3
4
5
6
7
8
9
10
MOTOR POWER CIRCUIT
PANEL LID
COMPONENT LIST
LABEL
DESCRIPTION
BK
WH
PUT END OF LINE PLUG IN
EMPTY RJ45 JACKS, PN: EOL120A
GR
UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG.
BK
BK
BK
BK
JUMPER
BK
BK
BL
PR
BK
WH
BK
WH
SWITCHES
CAT-5 CABLE. LENGTH AS REQUIRED.
DRY CONTACTS (SHOWN DE-ENERGIZED)
ON/OFF
WITH FIRE
ON/OFF
WITH
SUP
DRY CONTACTS (SHOWN DE-ENERGIZED)
PUT END OF LINE PLUG IN
EMPTY RJ45 JACKS, PN: EOL120A
SWITCHES
CAT-5 CABLE. LENGTH AS REQUIRED.
HMI 1HMI 1
JUMPER
MAKE UP AIR INTERLOCK.
NOTE: All items on ECPM03 J3 line to be daisy chained
from one component to the next, with EOL120A at end
of line. Place PN: EOL120A in empty RJ45 port.
FACTORY WIRING
SCHEMATIC
CIRCUIT BOARDS
ECPM03
DCV Rev. 1.12
HMI Rev. 2.03
CONTROL INPUT
120V H1=LINE,
N1=NEUTRAL, 15A
BREAKER. DO
NOT CONNECT
TO SHUNT TRIP
BREAKER. SEE
INSTALLATION
SCHEMATIC FOR
ADDITIONAL REQ.
NOTE: IF VFD HAS 1PH 240V INPUT, USE L1 & L2 ONLY.
IF VFD HAS 1PH 120V INPUT, USE L1 & N ONLY.
Demand Control
Ventilation, w/ 2
Exhaust Fans, 1 Supply
Fan, Exhaust on in Fire,
Lights out in Fire, Fans
modulate based on duct
temperature. INVERTER
DUTY THREE PHASE MOTOR
REQUIRED! Room
temperature sensor
shipped loose for field
installation.Verify
distance between VFD
and Motor; additional
cost could apply if
distance exceeds 50
feet.
SM-1 SM-2 SM-3
SC-24 X 18 X 8.62 BOX
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
www
.
ca
p
ti
v
ea
i
r
e
.
c
o
m
DATE:
A
CC
O
R
DAN
C
E
N
o
.
96
B
U
I
LT
N
FP
A
W
I
T
H
I
N
S
L
I
D
T
E
R
C
U
S
Your Title Date
SIGNATURE
Revise and Resubmit
Approved with NO Exception Taken
Approved as Noted
CUSTOMER APPROVAL TO MANUFACTURE:
All Hoods, Exhaust Fans, Tempered/Untempered
Make-Up Air Units and Electrical Packages to
Technician. Report to be sent to Engineer
by Commissioning Agent when complete.
be Commissioned by Factory Field Service
NASHVILLE REGIONAL OFFICE
128 HOLIDAY COURT, SUITE 115, FRANKLIN, TN 37067
PHONE: (615) 599-8300
FAX: (919) 227-5960
FOR QUESTIONS, CALL THE
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
BREAKER 1PH
CONTROL POWER. DO NOT WIRE
TO SHUNT TRIP BREAKER.
CONTROL POWER. SWITCH #1
1ST HOOD LIGHT BREAKER SHARED W/
BREAKER 3PH
WIRE TO VFD QUICK CONNECTOR
IF 1 PH 240 VAC INPUT, USE L1 & L2 ONLY.
IF 1 PH 120 VAC INPUT, USE L1 & N ONLY.
BREAKER 3PH
WIRE TO VFD QUICK CONNECTOR
IF 1 PH 240 VAC INPUT, USE L1 & L2 ONLY.
IF 1 PH 120 VAC INPUT, USE L1 & N ONLY.
BREAKER 3PH
WIRE TO VFD QUICK CONNECTOR
IF 1 PH 240 VAC INPUT, USE L1 & L2 ONLY.
IF 1 PH 120 VAC INPUT, USE L1 & N ONLY.
POWER TO
CONDENSER
POWER TO
CONDENSER
Load Wiring
WIRE TO
VFD QUICK
WIRE TO
DISCONNECT
CONNECTOR
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
FLA:
HP:
VOLT:
Load Wiring
WIRE TO
VFD QUICK
WIRE TO
DISCONNECT
CONNECTOR
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
FLA:
HP:
VOLT:
Load Wiring
BLACK
BLACK
BLACK
GREEN
WIRE TO
VFD QUICK
CONNECTOR
MUST HAVE ITS OWN METAL
CONDUIT. WIRE TO PROVIDED
CONDUIT DROP.
WHITE
RED
FLA:
HP:
VOLT:
MAKE UP AIR
PROVING
INTERLOCK
DAMPER
LOW VOLTAGE CONNECTION FOR
DAMPER INTERLOCK. SHOULD
HAVE CONTINUITY WHEN DAMPER
IS PROVEN OPEN.
IN MUA #1
TERMINAL NAMES
DO NOT APPLY
IF MUA BY OTHERS
ON PCB
NOT REQUIRED FOR ALL UNITS.
SEE MAKE-UP AIR SCHEMATIC.
REMOVE JUMPER
WIRE C1 TO COMMON (1).
C1 TO AR1 SHOULD HAVE
HOOD PANEL
FIRE SYSTEM
TO
MICROSWITCH
CONTINUITY WHEN ARMED.
IF MORE THAN ONE
WIRE AR1 TO NORMALLY CLOSED (2).
CAP
OFF
CAP
OFF
CAP
OFF
FIRE SYSTEM, WIRE
IN SERIES AS SHOWN
ALL SWITCHES FACTORY WIRED
CAT-5 CONNECTION
HOOD PANEL
SWITCHES
TO
HOOD PANEL
HOOD LIGHTS
TO
1400 W MAX
WIRE TO J-BOX ON TOP OF HOOD
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN ROOM AWAY
FROM HEAT SOURCES. SEE MANUAL
HOOD PANEL
KITCHEN TEMP
TO
SENSOR
FACTORY WIRED TEMPERATURE
SENSOR. MOUNTED IN EXHAUST DUCT
HOOD PANEL
DUCT SENSOR
TO
FACTORY WIRED TEMPERATURE
SENSOR. MOUNTED IN EXHAUST DUCT
HOOD PANEL
DUCT SENSOR
TO
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN EXHAUST DUCT
HOOD PANEL
DUCT SENSOR
TO
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN EXHAUST DUCT
HOOD PANEL
DUCT SENSOR
TO
HOOD PANEL
PSP LED
TO
LIGHTS
WIRE TO J-BOX ON TOP OF PSP.
CONNECT TO RESPECTIVE HOOD
LIGHTING CIRCUIT. NOTE: DO NOT
HOOD
LIGHT
INPUT
MATCH
WIRE IN SERIES WITH HOOD LIGHTS.
THE FOLLOWING CONNECTIONS
MAY OR MAY NOT BE
REQUIRED BASED ON JOBSITE
SPECIFICATIONS
HOOD PANEL
EXTERNAL
SIGNAL FOR
SHUNT TRIP
ST TERMINAL IS ENERGIZED
IN FIRE CONDITION.
SPARE CONTACTS USED WHEN FIRE
HOOD PANEL
SYSTEM DRY
SPARE FIRE
CONTACT
SYSTEM DISCHARGES TO DISABLE
EQUIPMENT OR PROVIDE SIGNALS.
(NOT FOR BUILDING FIRE ALARM)
SPARE CONTACTS WILL MAKE
HOOD PANEL
ON/OFF WITH
DRY CONTACT
SUPPLY FAN
COMMON TO NORMALLY OPEN
WHEN SUPPLY FAN IS ON.
GROUP 1
WIRE TO ECPM03 TERMINALS.
CONFIGURABLE OUTPUT.
EMS SPEED
(TOTAL)
0-10V OUTPUT
ON PCB
SEE ECPM03 OWNERS MANUAL.
TO BMS
+
-
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
WIRE TO VFD TERMINAL STRIP.
PROPORTIONAL TO FREQUENCY.
VFD ANALOG
(EACH VFD)
0-10V OUTPUT
IN VFD
SEE VFD OWNERS MANUAL.
TO BMS
+
-
PN:
PN:
PN:
PN:
PN:
RELAY
120 VAC
NO
COM
COIL
NC
34
6 5
8
2
7
1
RA-x
RELAY
24 VDC
NO
COM
COIL
NC
12
14
11
A2A1
RD-x
+
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK YW- YELLOW
BL- BLUE GY- GREY
BR- BROWN PR- PURPLE
OR- ORANGE RD- RED
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
PN:
PN:
L
N
+
-
PN:
1
2
11
1
JUMPER
1
2
11
1
JUMPER
1
2
11
1
JUMPER
DWG NO
JOB NO
DATE
DRAWN BY
JOB NAME
DESCRIPTION OF OPERATION
TYPE
DRAWING TITLE
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
U/T1
V/T2
W/T3
L1
L2
L3/N
GR
GR
GND
VFD:
HP:
MTR:
FLA:
P107:
P108:
P150:
P100:
P410:
P194:
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
U/T1
V/T2
W/T3
L1
L2
L3/N
GR
GR
GND
VFD:
HP:
MTR:
FLA:
P107:
P108:
P150:
P100:
P410:
P194:
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
U/T1
V/T2
W/T3
L1
L2
L3/N
GR
GR
GND
VFD:
HP:
MTR:
FLA:
P107:
P108:
P410:
P150:
P100:
P194:
RANGEHOOD MAKE-UP/EXHAUST UNIT CONTROL
PL
EF
N.C.
F.A.C.
FUSE
S.F.
30 O.L.
30 O.L.
N.O.
E.F. AUX. CONT.
N.O.
N.C.
F.S.C.
EXHAUST FAN
PILOT LIGHT
SUPPLY FAN
AUX. CONTACT
480/120V XFMR OR
208/120 V XFMR
F.S.C.- FIRE SUPPRESSION RELAY CONTACT
E.F. - EXHAUST FAN
S.F. - SUPPLY FAN (MAKE-UP AIR)
F.A.C.- FIRE ALARM CONTACT IN CONTROL MODULE
N.O. - NORMALLY OPEN CONTACT
N.C. - NORMALLY CLOSED CONTACT
F.S.C.
N.O.
C9A
SCALE:
NONE
ON CANOPY
CONTROL
"ON/OFF"
EXHAUST FAN
MAKE-UP AIR UNIT
IN INTAKE OF
N.C. O.A. DAMPER
NOTE: ALL WIRING BY DIVISION 16. AMPACITY OF RELAY CONTACTS SHALL MATCH CIRCUIT RATINGS.
FIRE SUPRESSION SYSTEM
C
S.T.
TO MAKE-UP
AIR UNIT
120V
N.O.
FIRE SUPRESSION
CONTROL BOX
FIRE SUPRESSION
RELAY
MECHANICAL CABLE
MECHANICAL GAS VA.
FUSIBLE LINKS
N.O.
N.O.
N.O.
N.C.
TO HOOD E.F.
(SHUNT TRIP
CIRCUIT)
TO FIRE ALARM
SYSTEM ADAPTER
MODULE
MANUAL PULL STATION
LOCATE 10' MIN AND
20' MAX FROM HOOD
C9B
SCALE:
NONE
UNDER HOOD
CIRCUITS
ELECTRIC
COILS- ALL
TO SHUNT-TRIP
NOTE: ALL WIRING BY DIVISION 16. AMPACITY OF RELAY CONTACTS SHALL MATCH CIRCUIT RATINGS.
WITH HOOD MOUNTED PANEL
TYPICAL SC-DEMAND CONTROL VENTILATION
TEMPERATURE SENSOR
TEMPERATURE SENSOR
HOOD LIGHTS
CONTROL PANEL
CASHMI
INTERFACE
ROOM TEMPERATURE
SENSOR
FIELD WIRED CONNECTIONS
DCV Specification
Demand Ventilation System
Application:
The Demand Ventilation System is designed to automatically reduce exhaust and supply airflow
quantities, while ensuring hood performance is maintained. The DCV uses Variable Frequency Drives
(VFD) and temperature sensors in the exhaust ducts to modulate the fans speed during cooking
operation and maximize energy savings. The DCV LCD screen interface provides fan(s) control, system
configuration, and diagnostic information.
Construction:
The DCV includes:
- A smart Controller
- LCD Screen Interface
- Duct Temperature Sensor(s)
- Room Temperature Sensor
- Variable Frequency Drive(s)
Controls will be listed by ETL to UL standard 508A.
The system includes a LCD screen interface for fan(s) and hood lights control, wash control (if
applicable), gas valve reset, programmable schedule, Max Air Override function, Preparation Time mode,
Cool Down mode, and diagnostics including VFD status. The LCD screen shows descriptive plain text
explaining the functions or values. The LCD screen interface will be installed on the face of the hood, on
the face of the utility cabinet or on the face of a wall mounted control enclosure.
Control enclosure will be NEMA 1 rated and listed for installation inside of the exhaust hood utility cabinet.
Control enclosure may be constructed of stainless steel or painted steel.
The smart controller will constantly monitor the exhaust air temperature through the riser mounted
temperature sensor and modulate the fan speeds accordingly.
A room temperature sensor will also be provided for field installation in the kitchen space in order to start
the fan(s) based on the temperature differential between the room and the exhaust air in the duct rather
than fixed set-points.
A Preparation Time Mode is available for morning operation: dedicated make-up air will be locked out
only allowing the use of transfer air during this mode. Exhaust fan(s) will run at low CFM while
maintaining a balanced kitchen pressure.
A Cool Down Mode is designed for equipment cool-down period at the end of the daily cooking
operations: similarly to Preparation Time mode, dedicated make-up air will be locked out only allowing the
use of transfer air during this mode. Exhaust fan(s) will run at low CFM while maintaining a balanced
kitchen pressure.
Fan maximum/ minimum speeds will be adjustable for proper kitchen balance. Fan direction change is
also available from the smart controller configuration menu without need for rewiring.
Duct Temperature Sensor(s) will be mounted in the exhaust hood riser(s). Temperature probe will be
constructed of Stainless Steel. System will be factory pre-set to modulate fan speed within a range of
45°F for 600°F and 700°F cooking applications and a range of 5°F for 400°F cooking applications. Setpoints
are fully adjustable through the touch screen interface based on application needs.
The Max Air Override will have an adjustable timeout value.
The panels include color coded wiring with as-built wiring diagrams and spare terminals controlled by the
fire system micro switch. The panel is factory pre-wired to shut supply fans down in a fire condition.
Options to turn ON the exhaust fans or turn off the hood lights in a fire condition will be configurable
through the smart controller, but only through a password protected menu to prevent any changes after a
fire inspection has been performed.
Duct Temp Sensor to be
installed in every exhaust
riser. All Duct Temp
Sensors and Hood Lights to
be wired back to SC-DCV
Electrical Control Box.
ELECTRICAL PACKAGES - Job#1952645
1
EMS1
DCV-2111
Utility Cabinet Left
Utility Cabinet Left
Hood # 1
1 Light
1 Fan
Smart Controls DCV
Exhaust
Exhaust
Supply
3
3
3
1.500
1.500
3.000
460
460
460
2.2
2.2
4.7
NO.
TAG
PACKAGE #
LOCATION
SWITCHES
LOCATION
QUANTITY
OPTION
FANS CONTROLLED
TYPE
H.P.
VOLT
FLA
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
www
.
ca
p
ti
v
ea
i
r
e
.
c
o
m
DATE:
A
CC
O
R
DAN
C
E
N
o
.
96
B
U
I
LT
N
FP
A
W
I
T
H
I
N
S
L
I
D
T
E
R
C
U
S
HOOD LIGHTS
FIELD WIRED CONNECTIONS
Room Override Thermostat
Your Title Date
SIGNATURE
Revise and Resubmit
Approved with NO Exception Taken
Approved as Noted
CUSTOMER APPROVAL TO MANUFACTURE:
All Hoods, Exhaust Fans, Tempered/Untempered
Make-Up Air Units and Electrical Packages to
Technician. Report to be sent to Engineer
by Commissioning Agent when complete.
be Commissioned by Factory Field Service
NASHVILLE REGIONAL OFFICE
128 HOLIDAY COURT, SUITE 115, FRANKLIN, TN 37067
PHONE: (615) 599-8300
FAX: (919) 227-5960
FOR QUESTIONS, CALL THE
FANS
LIGHTS
with LCD Screen
HOOD CONTROL PACKAGE INTERFACE
GANG JUNCTION BOX
CAN MOUNT IN STANDARD DOUBLE
MODEL TYPE.
BUTTON FUNCTIONS VARY BY
ALARM INDICATING LCD SCREEN.
PANEL.
CONNECTED TO HOOD CONTROL
CAT-5 CONNECTION ON REVERSE.
**NOTE: EXTENSION
RING TO BE
TACK WELDED
TO DUCT OR
RISER
NOTE: Thermistor has 2 wires that connect to control cabinet
DUCT THERMISTOR SENSOR INSTALLATION
Grease Duct
(External Surface)
1/2" NPT Quik Seal (Adapter Body)
Part # 32-00002
1/2" Quik Seal (Gasket)
Part # 32-00002
1/2" Quik Seal (Lock Washer)
Part #32-00002
1/2" NPT Quik Seal (Nut)
Part #32-00002
1 1/8" - 1 1/4" Diameter Hole
Thermistor Temperature
Sensor
Part #
A/CP- PO-T4"-EXPL
Extension Ring
59361-1/2
Extension Ring Cover
100-BW
2"
3.25"
reading is accurate for space.
the electrical control box) so the
hood or close to an appliance (including
the space but not directly under the
on a wall, 5'-6' off the finished floor, in
room and duct. Installed by electrician
temperature differential between the
Provides room override based on
M4.4
MARSHALL'S OFFICE.
AND INCLUDED AS A REQUIREMENT OF THE TN STATE FIRE
THE DRAWINGS ON THIS SHEET WERE PREPARED BY CAPTIVE AIRE
NOTE:
5
:
48
:
07
P
M
4
/
8
/
2014
G
:\
13264
\
13264
m
50
.
004
.
dgn
8
:
0
'
:
"
/
i
n
.
r
s
ou
t
h
a
ll
THIS DRAWING SHALL NOT BE
REPRODUCED, PUBLISHED, OR USED
IN ANY WAY WITHOUT THE WRITTEN
PERMISSION OF THE ARCHITECT.
PROJECT N0.
DATE
REVISION
CHECKED BY
DRAWN BY
DATE
NOTES:
1311
E.E.I.
E.E.I.
School
Intermediate
Hill
Chapel
04-08-14
Chapel Hill, Tennessee
425 South Horton Parkway
L
.
H
U
N
T
I
M
J
N
E
B
1
0
2
7
.
o
N
N
A
E
R
3
9
4/8/14