Specifications
KEY PLAN
AREA D
AREA B
AREA A
AREA C
TYPICAL CLASSROOM
863 SQ. FT.
A106
CLASSROOM 1
GRADE
FOURTH
A106A
CL.
A107
MECH.
A108A
CL.
A108
CLASSROOM 2
GRADE
FOURTH
A110
TOILET
GIRLS
A111
TOILET
BOYS
B120A
I.D.F.
B102B
STORAGE
A105
CLASSROOM 3
GRADE
FOURTH
A103
CLASSROOM 4
GRADE
FOURTH
A103A
CL.
A105A
CL.
A104
MECH.
A102
MECH.
A101A
CL.
A101
CLASSROOM 5
GRADE
FOURTH
A113
CORRIDOR
A109
HAND WASHING
A112
ERV
MECH.
FD
FD
FD
FD
D116A
CL.
D117
MECH.
D116
CLASSROOM 5
GRADE
SIXTH
D115
TOILET
BOYS
D114
TOILET
GIRLS
D113
HAND WASHING
D111A
CL.
D112
MECH.
D111
CLASSROOM 4
GRADE
SIXTH
D110
CLASSROOM 3
GRADE
SIXTH
D109
MECH.
D110A
CL.
D107
CLASSROOM
C.D.C.
D108
TLT.
D105
I.D.F.
D106
MECH.
D104
CLASSROOM 2
GRADE
SIXTH
D104A
CL.
D103
MECH.
D102A
CL.
D102
CLASSROOM 1
GRADE
SIXTH
D101
ERV
MECH.
C
O
RR
I
DO
R
D
118
FD
FD
FD
FD
FD
WASHER/DRYER
REFRIG.
H.V.A.C.
H.V.A.C.
M2.1
(TYPICAL ALL MECHANICAL SPACES)
AND SERVICE ACCESS TO EQUIPMENT.
& PIPE COORDINATION WITH ALL TRADES
SPACES TO CONFIRM EQUIPMENT, DUCT
PROVIDE SHOP DRAWING OF MECHANICAL
I. SEE M3.1 FOR T'STAT LOCATIONS.
H. SEE SHEET M4.1 FOR TYPICAL CLASSROOM MECHANICAL ROOM LARGE SCALE PLAN.
AIR INLETS REBALANCED PROPORTIONALLY LOWER TO ACCOUNT FOR DIFFERENCE.
CONDITIONS AS INDICATED ON THE DRAWINGS AND THEN THE OUTSIDE AIR BALANCED WITH RETURN
G. TESTING ADJUSTING & BALANCING OF AIR SHALL INITIALLY BE ACCOMPLISHED AT UNOCCUPIED
F. REFERENCE ARCHITECTURAL ELEVATIONS FOR LOCATIONS OF LOUVERS AND WALL CAPS.
E. REFERENCE CONTROL SCHEMATICS & DUCTWORK DETAILS FOR MANUAL & AUTOMATIC DAMPER LOCATIONS.
110.26. PROVIDE MECHANICAL ROOM SHOP DRAWINGS AS REQUIRED FOR COORDINATION.
D. MAINTAIN CLEARANCES FOR SERVICE OF HVAC EQUIPMENT AS REQUIRED BY MANUFACTURER AND NEC
C. MAINTAIN CLEARANCES FROM ELECTRICAL PANELS AS REQUIRED BY N.E.C.
ANY AIR OUTLETS WITHIN 3 FEET OF CEILING SMOKE DETECTORS.
B. COORDINATE CEILING AIR INLETS AND OUTLETS WITH REFLECTED CEILING PLAN. DO NOT LOCATE
FOR REVIEW.
CHANGES IN DUCT ROUTING OR DUCT SIZING AS A SHOP DRAWING TO THE ARCHITECT/ENGINEER
A. COORDINATE DUCTWORK WITH ALL TRADES PRIOR TO FABRICATION. SUBMIT ANY MAJOR
GENERAL NOTES:
00
SCALE 1/8" = 1'- 0"
4'8' 8'
16'
FLOOR PLAN AREA - A
00
SCALE 1/8" = 1'- 0"
4'8' 8'
16'
FLOOR PLAN AREA - D
M
A
T
C
H
L
I
N
E
P
A
R
T
A
P
A
R
T
B
12
:
10
:
18
P
M
4
/
9
/
2014
G
:\
13264
\
13264
M
10_
AD
1
.
DGN
8
:
0
'
:
"
/
i
n
.
r
s
ou
t
h
a
ll
THIS DRAWING SHALL NOT BE
REPRODUCED, PUBLISHED, OR USED
IN ANY WAY WITHOUT THE WRITTEN
PERMISSION OF THE ARCHITECT.
PROJECT N0.
DATE
REVISION
CHECKED BY
DRAWN BY
DATE
NOTES:
1311
E.E.I.
E.E.I.
School
Intermediate
Hill
Chapel
04-08-14
Chapel Hill, Tennessee
425 South Horton Parkway
L
.
H
U
N
T
I
M
J
N
E
B
1
0
2
7
.
o
N
N
A
E
R
3
9
4/8/14
MATCHLINE ALTERNATE 1
BASE
MATCHLINE
PART B
PART D
C.M.U. WITH BRICK/STONE VENEER EXTERIOR WALL
C.M.U. WALL - TWO HOUR FIRE RATED
C.M.U. WALL - ONE HOUR FIRE RATED
C.M.U. WALL - NOT FIRE RATED
WALL SYMBOLS LEGEND
* UTILIZE BULLNOSE C.M.U. FOR ALL EXPOSED 90 DEGREEE C.M.U. CORNERS
C.M.U. WALL - TOILET PARTITION
COURSE ABOVE CEILING- APPLIES TO ANY WALL TYPE
EXTEND HEIGHT OF THIS WALL TO A HEIGHT OF 1CMU
BOTTOM TRUSS CORD, UNLESS NOTED OTHERWISE.
METAL TRUSS ROOF SYSTEM TIGHT TO GYPSUM BOARD AT
* EXTEND ALL WALLS (C.M.U. & METAL STUD) AT AREAS WITH
WITH 1 HOUR FIRE RATED C.M.U.
* INTERIOR LOAD BEARING WALLS SHALL BE CONSTRUCTED
WITH 2 HOUR FIRE RATED C.M.U.
* EXTERIOR LOAD BEARING WALLS SHALL BE CONSTRUCTED
W/ METAL STUD/GYPSUM WALLBOARD WALL
ABOVE CEILING. EXTEND TO STRUCTURE ABOVE
EXTEND TO A HEIGHT OF 1CMU COURSE
C.M.U. WALL NON-LOAD BEARING
C.M.U. WALL - SMOKE PARTITION
C.M.U. WALL - THREE HOUR FIRE BARRIER
24X14EA
24X14OA
MIN.6 SQ.FT.F.A.
72X24 OA LOUVER
MIN.6 SQ.FT.F.A.
72X24 EA LOUVER
450E
12X12
300E
12X12
HP-A1
HP-A2
HP-A3 HP-A4
HP-A5
SDH-A1
HP-A6
BLOWER ACCESS
COMPRESSOR/CONTROL ACCESS
C
O
M
P
/
C
T
R
L
A
CC
E
SS
B
L
O
W
E
R
&
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
18X12 18X12
200
8"Ê
200
8"Ê
ERV-A1
800
16"Ê
800
16"Ê
18X18
14X18
12X18
12X14
10X10
18X12
260E
12X12
260E
12X12
260E
12X12
260E
12X12
260E
12X12
12X10 12X12
16X14
14X10
20X16
20X16
14X12
18X12
26X14
8"Ê
EXPANSION
FUTURE
CAPPED FOR
1825R
24X24
125
8"Ê
18X12
12X12
18X12
12X12
12X12 12X12 12X12
10"Ê10"Ê
10"Ê
10"Ê 10"Ê
10"Ê
10"Ê
10"Ê
18X16
SD
T
HP-D4
HP-B3
MIN.6 SQ.FT.F.A.
72X24 OA LOUVER
MIN.6 SQ.FT.F.A.
72X24 EA LOUVER
450E
12X12
300E
12X12
HP-D3
SDH-D1
HP-D1
HP-D2
HP-D5
HP-D6
HP-D7
EH#D1
B
L
O
W
E
R
A
CC
E
SS
C
O
M
P
R
E
SS
O
R
/
C
ON
T
R
O
L
A
CC
E
SS
VENT
4"Ê DRYER
125
8"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
400
12"Ê
ERV-D1
40
X
14
OA
10"Ê
18X14
8"Ê
10"Ê
20X14
14X12
10"Ê
10"Ê
32X14
10"Ê
10"Ê
200
8"Ê
200
8"Ê
125
8"Ê
375
10"Ê
1800R
24X24
285E
12X12
285E
12X12
285E
12X12
285E
12X12
285E
12X12
400
10"Ê
18X12
18X12
18X12
18X12 18X12
18X12
200E
12X12
75E
12X12
350
10"Ê
350
10"Ê
325R
12X12
12X12
12X12
12X12
12X12 12X12
12X12
8X12
8X12
10X10
26X12
18X12
12X12
36X12
8X8
200 CFM
10X6 SAR
26X16
16X16
26X12
10"Ê
10"Ê
10"Ê10"Ê
10"Ê
450E
12X12
10X10
10"Ê
75E
12X12
6"Ê
6"Ê
8"Ê
20X12
14X12
24X12
24X12
20X12
14X12
26X14
26
X
14
E
A
12X12
LOUVER
16X16 EA
10"Ê
10"Ê
22X18
SD
SD
SD