Specifications

TYPICAL CLASSROOM
863 SQ. FT.
212 BLEACHER SEATS
PLAYROOM
WASH
CAN
TRANS.
MTD.
PAD
3' SOLID GATE
A106
CLASSROOM 1
GRADE
FOURTH
A106A
CL.
A107
MECH.
A108A
CL.
A108
CLASSROOM 2
GRADE
FOURTH
A110
TOILET
GIRLS
A111
TOILET
BOYS
B120A
I.D.F.
B102B
STORAGE
A105
CLASSROOM 3
GRADE
FOURTH
A103
CLASSROOM 4
GRADE
FOURTH
A103A
CL.
A105A
CL.
A104
MECH.
A102
MECH.
A101A
CL.
A101
CLASSROOM 5
GRADE
FOURTH
A113
CORRIDOR
A109
HAND WASHING
B142
WAITING
B100
VESTIBULE
B143
RECPT.
B141
OFFICE
B140
OFFICE
PRIN.
ASST.
B139
TLT.
B138
TLT.
B136
WAIT.
GUID.
B135
OFFICE
GUID.
B134
CLINIC
B134A
TLT.
B144
CONF.
B137
MAIL
CORRIDOR B133
B148
OFFICE
B150
MECH.
B145
OFFICE
PRIN.
B145A
TLT.
B146
RECORDS
B147
KEEPING
BOOK
CORRIDOR B149
D116A
CL.
D117
MECH.
D116
CLASSROOM 5
GRADE
SIXTH
D115
TOILET
BOYS
D114
TOILET
GIRLS
D113
HAND WASHING
D111A
CL.
D112
MECH.
D111
CLASSROOM 4
GRADE
SIXTH
D110
CLASSROOM 3
GRADE
SIXTH
D109
MECH.
D110A
CL.
D107
CLASSROOM
C.D.C.
D108
TLT.
D105
I.D.F.
D106
MECH.
D104
CLASSROOM 2
GRADE
SIXTH
D104A
CL.
D103
MECH.
D102A
CL.
D102
CLASSROOM 1
GRADE
SIXTH
D101
ERV
MECH.
B132
ELEC.
B131
B.M.S.
B128A
CL.
B129
MECH.
B128
CLASSROOM 3
GRADE
FIFTH
B127
CLASSROOM 4
GRADE
FIFTH
B127A
CL.
B125A
CL.
B126
MECH.
B125
CLASSROOM 5
GRADE
FIFTH
B123
CLASSROOM 6
GRADE
FIFTH
B123A
CL.
B124
MECH.
B130
CORRIDOR
B121
MECH.
B122A
CL.
B122
CLASSROOM 2
GRADE
FIFTH
B120
CLASSROOM 1
GRADE
FIFTH
B120A
CL.
B119
MECH.
B116
HAND WASHING
B118
TOILET
BOYS
B117
TOILET
GIRLS
B115
I.D.F.
B114
TLT.
B111
T.W.A.
B113
TLT.
B112
STORAGE
B157
ERV
MECHANICAL
B
15
5
A
C
L
.
B
15
6
M
E
C
H
.
B155
CLASSROOM
COMPUTER
B151
ERV
MECHANICAL
B
15
3
M
E
C
H
.
B
152
E
DU
C
A
T
I
O
N
SP
E
C
I
A
L
B
154
E
D
U
C
A
T
I
ON
S
P
E
C
I
A
L
B110
OFFICE
MEDIA
B106
CENTER
MEDIA
C
O
R
R
I
D
O
R
B
15
8
B107
TLT.
B108
WORK ROOM
B105
ROOM
MDF
I.T.
B104
AUDIO/VIS.
B103
MECH.
B109
STORAGE
BOOK
C102A
STORAGE
2,809 SQ. FT.
B102
CAFETERIA
C102
ART
C131
SERVING
C130
DISHWASHING
C129
STORAGE
NON-FOOD
C127
STORAGE
COLD
C128
PREP.
FOOD
C120
MECH.
C123
OFFICE
C124
TLT.
C125
LOCKER
C121
STORAGE
OUTDOOR
C122
STORAGE
DRY FOOD
C119
ELEC.
MECH.
CORRIDOR C118
C117
STORAGE
SUPPLIES
C111
PLATFORM
C113
MECH.
C115
OFFICE
P.E.
C116
STORAGE
P.E.
C109
AREA
ENTRY
C112
RAMP
C106
WASHING
HAND
C107
TOILET
BOYS
C104
MUSIC
C104A
CL.
C103
MECH.
C
O
RR
I
DO
R
C
126
C
O
RR
I
DO
R
C
101
ADDITION
CLASSROOM
FUTURE FOUR
ADDITION
CLASSROOM
FUTURE FOUR
ADDITION
CLASSROOM
FUTURE SIX
A112
ERV
MECH.
B101
LOBBY
C
O
RR
I
DO
R
D
118
D110
CLASSROOM 3
GRADE
SIXTH
D110A
CL.
D111
CLASSROOM 4
GRADE
SIXTH
D111A
CL.
D109
MECH.
D112
MECH.
D119
CLASSROOM
GRADE
SIXTH
D119A
CL.
C
O
RR
I
DO
R
D
118
D120
CLASSROOM
GRADE
SIXTH
D120A
CL.
D107
C.D.C. CLASSROOM
D114
GIRLS TOILET
C108
TOILET
GIRLS
C113
MEZZANINE
MECH.
C119A
ELEC.
C132
RISER ROOM
SPRINKLER
(N.I.C.)
COPIER
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
WASHER/DRYER
REFRIG.
REFRIG.
W
A
S
H
E
R
/
D
R
Y
E
R
WASHER/DRYER
REFRIG.
HATCH
ACCESS
ATTIC
D111 AND D110 WILL BE CONSTRUCTED AS SHOWN BELOW.
CLASSROOMS OF D119 AND D120) IS ACCEPTED, BASE BID CLASSROOMS
ON THE CONDITION THAT ALTERNATE ONE(1) (TWO ADDITIONAL
T
T
T
T
T
T
T
T
T
H.V.A.C. PIPING
T
T
T
T
M3.1
"
2
1
2
RISE/DROP
3"
8"
8"
6"
4"
3"
FUTURE (36 GPM)
" CAPPED FOR
2
1
2
FUTURE (36 GPM)
" CAPPED FOR
2
1
2
2"
6"
4"
4"
3"
3"
"
2
1
2
2"
2"
"
2
1
1
"
2
1
2
4"
2"
3"
FUTURE (54 GPM)
3" CAPPED FOR
4"
"
2
1
1
4"
4"
3"
3"
8"
"
2
1
1
3"
"
2
1
1
HP-A3 HP-A4
HP-A2HP-A1
HP-A5
HP-A6
ERV-A1
SDH-A1
HP-B15
HP-B16
HP-B17
HP-B18
HP-C2
HP-C3
HP-C1
KMUA#1
EH#C3
EH#C4
SDH-C1
ERV-C1
HP-C4
EH#C2
EH#C1
HP-B13
HP-B14
HP-B12
HP-B19
HP-B11
HP-B7
HP-B8
HP-B6HP-B5
HP-B9
HP-B10
HP-B4
SDH-D1
HP-B3
HP-B2
HP-B1
HP-D3
HP-D2
HP-D1
EH#D1
HP-D7HP-D6
HP-D5
HP-D4
SDH-B1
AIR/DIRT SEP.
SPIROVENT COMB.
"
2
1
2
"
2
1
2
3000CFM
ERV-D1
3000CFM
ERV-B1
HP-D6 HP-D7
HP-D8 HP-D9
DRAIN VALVE.
D. ALL LOW POINTS IN PIPING-SYSTEM SHALL HAVE BALL
CONTROLS VENDOR AND ELECTRICAL CONTRACTOR.
C. COORDINATE LOCATION OF D.D.C. PANELS WITH
PIPING CONFIGURATIONS & T'STAT LOCATIONS.
B. REFERENCE TYPICAL MECH. ROOM LARGE SCALE FOR
PER N.E.C.
FROM ELECTRICAL PANELS & FUSED DISCONNECTS
TO FABRICATION OF PIPE. MAINTAIN CLEARANCE
A. COORDINATE ROUTING WITH OTHER TRADES PRIOR
GENERAL HVAC PIPING NOTES:
T
CO2
DDC PANEL
T
T
T
TEMPS WITH ALARM
COOLER/FREEZER
"
2
1
1
MEZZANINE LEVEL
UP TO EQUIPMENT ON
HP-C5
TO HP-C6
(TYPICAL)
ISOLATION VALVES
T
00
OVERALL FLOOR PLAN
SCALE 1/16" = 1'- 0"
16' 32'
8'
16'
MATCHLINE ALTERNATE 1
BASE
ALTERNATE
NO. 1
MATCHLINE ALTERNATE 1
BASE
ALTERNATE
NO. 1
MATCHLINE
PART B
PART D
MATCHLINE
PART C
PART B
M
A
T
C
H
L
I
N
E
P
A
R
T
A
P
A
R
T
B
12
:
09
:
34
P
M
4
/
9
/
2014
G
:\
13264
\
13264
m
1p_
X
01
.
dgn
16
:
0
'
:
"
/
i
n
.
r
s
ou
t
h
a
ll
THIS DRAWING SHALL NOT BE
REPRODUCED, PUBLISHED, OR USED
IN ANY WAY WITHOUT THE WRITTEN
PERMISSION OF THE ARCHITECT.
PROJECT N0.
DATE
REVISION
CHECKED BY
DRAWN BY
DATE
NOTES:
1311
E.E.I.
E.E.I.
School
Intermediate
Hill
Chapel
04-08-14
Chapel Hill, Tennessee
425 South Horton Parkway
L
.
H
U
N
T
I
M
J
N
E
B
1
0
2
7
.
o
N
N
A
E
R
3
9
4/8/14
C.M.U. WITH BRICK/STONE VENEER EXTERIOR WALL
C.M.U. WALL - TWO HOUR FIRE RATED
C.M.U. WALL - ONE HOUR FIRE RATED
C.M.U. WALL - NOT FIRE RATED
WALL SYMBOLS LEGEND
* UTILIZE BULLNOSE C.M.U. FOR ALL EXPOSED 90 DEGREEE C.M.U. CORNERS
C.M.U. WALL - TOILET PARTITION
COURSE ABOVE CEILING- APPLIES TO ANY WALL TYPE
EXTEND HEIGHT OF THIS WALL TO A HEIGHT OF 1CMU
BOTTOM TRUSS CORD, UNLESS NOTED OTHERWISE.
METAL TRUSS ROOF SYSTEM TIGHT TO GYPSUM BOARD AT
* EXTEND ALL WALLS (C.M.U. & METAL STUD) AT AREAS WITH
WITH 1 HOUR FIRE RATED C.M.U.
* INTERIOR LOAD BEARING WALLS SHALL BE CONSTRUCTED
WITH 2 HOUR FIRE RATED C.M.U.
* EXTERIOR LOAD BEARING WALLS SHALL BE CONSTRUCTED
W/ METAL STUD/GYPSUM WALLBOARD WALL
ABOVE CEILING. EXTEND TO STRUCTURE ABOVE
EXTEND TO A HEIGHT OF 1CMU COURSE
C.M.U. WALL NON-LOAD BEARING
C.M.U. WALL - SMOKE PARTITION
C.M.U. WALL - THREE HOUR FIRE BARRIER