INSTALLATION AND OPERATION GUIDELINES
Read all instructions before installing tub. Installer / product owner is responsible for complying with all
state and local codes. Warranty coverage will be void if unit is not tested and installed per the enclosed
instructions. MTI strongly recommends using licensed professionals to install this product. Warning:
Certain cleaning products will permanently damage the acrylic surface. Read product label
carefully before using any cleaning product. Never use anything abrasive, aerosol sprays or any
product that is described as “scrubbing bubbles”. The use of products containing strong, natural
or articial dyes may discolor jets and/or controls. Please use with caution.
MTI does not warrant leaks associated with improper waste and overow installation.
Never leave a full or filling bath unattended.
BEFORE INSTALLING, INSPECT TUB THOROUGHLY
A. Damage from shipping or delivery must be reported to carrier immediately. Do not install
damaged tub. MTI is not responsible for damage occurring in transit.
B. Factory defect must be reported to factory before tub is installed. Defects or damage claimed
after installation will be excluded from warranty.
C. Important - Measure tub on site carefully before framing or cutting any deck materials.
Specifications are subject to change without notice. MTI Baths is NOT responsible
for any preparatory labor or materials.
ATTENTION INSTALLER!
THIS TUB MUST BE TESTED FOR OPERATION AND LEAKS PRIOR TO ENCLOSURE OF
SURROUNDING AREAS. FAILURE TO DO SO WILL VOID WARRANTY. THIS TUB WAS WATER
TESTED AT THE FACTORY AND FOUND TO BE FULLY OPERATIONAL AND LEAK-FREE PRIOR
TO SHIPPING. FREIGHT, HANDLING AND JOB SITE EXPOSURE MAY HAVE DETERIORATED THE
TUB’S CONDITION. IT IS THE RESPONSIBILITY OF THE INSTALLER TO THOROUGHLY TEST
THE UNIT PRIOR TO INSTALLATION. TUBS ARE INTENDED FOR INDOOR USE ONLY. TUBS ARE
WARRANTED FOR INDOOR INSTALLATION IN A CLIMATE CONTROLLED ENVIRONMENT ONLY.
PRODUCT FAILURES DUE TO IMPROPER INSTALLATION ARE NOT COVERED UNDER WARRANTY.
TEST PROCEDURES
1. Place the tub on a flat surface such as the driveway.
2. Seal the drain with tape.
3. Fill tub to overflow and allow tub to stand for five minutes without the pump or blower running. Examine
all fittings carefully for leaks. NOTE: The overflow is a plumbing device designed to help prevent water from
reaching a certain level in your tub. DO NOT, under any circumstances, tape off or block the overflow in
any way.
4. Any controls located above the normal water line are designed to be water-resistant, not water-proof. The
controls will not leak under normal usage, however, they are not warranted against leaks when improperly
used or subjected to conditions for which they were not designed.
5. Plug in the pump, blower and any other components into a 110v GFCI outlet. Start the equipment
and check all fittings for leaks.
6. Check that all optional equipment is functioning properly and that the features on the tub match
exactly what was ordered.
7. If any leaks or operating problems are discovered, do not complete installation until problems
are resolved. MTI will not be responsible for leaks claimed after the tub is installed, nor any costs
involved with removing or reinstalling the tub or the costs of any surrounding materials or labor.
See troubleshooting section of this manual or call for assistance: 800-783-8827