2 Installation
2.1 Cable Connection to BDA
2.1.1 Connection of RF cable to BDA
Input and output of BDA is fit for interface with N-type RF cable. Signal of RAS DL/UL path
at antenna connection cable is fed/transmitted to/from “LINK ANT” at BDA bottom side of
enclosure and amplified signal from BDA is fed/transmitted to/from “SERVICE ANT” port to
service area at BDA bottom side of enclosure.(Refer to Figure 10).
z Interfacing with link and service antenna
Figure 7 Interfacing with Link antenna and Service antenna
z RG 400 or similar quality of coaxial cable (50ohm) is recommended for the link and
service antenna connection.
z “LINK ANT” and “SERVICE ANT” antenna port of BDA is to be connected to the link
and service antenna with RF cable. Refer to the above figure for the connection port
at the unit.
Figure 8 Interfacing port of top side