User's Manual

BDA Installation and Operating Guide
Version 1.0 5
1 Pre-installation Consideration
Prepare the proper ground prior to installation of the BDA; the ground must be independent from
that for other equipment (Do not use common ground with others). The ground must be
connected with AWG 6 or AWG 8 multi-wired cable. The cord must not be parallel to other
electrical or RF cable. Do not apply the electric power without connecting output port of BDA to
Antenna or Dummy Load. The system will be stabilized in 5 minutes after power is switched on.
Before operation of the BDA, ensure that RF connectors and cables are not damaged and
properly connected.
DO NOT FASTEN OR UNFASTEN THE COAXIAL CABLE CONNECTOR
ON THE BDA WITH UNDER THE UNIT POWERED EQUIPMENT.
EXTREME CARE MUST BE TAKEN TO AVOID ELECTRIC SHOCK.
MAKE SURE THAT POWER SUPPLIER I N BDA UNIT IS TURNED OFF PRI OR
TO CONNECTI NG THE COAXI AL CABLE TO THE CABLE ENTRY
CONNECTOR ON BDA ENCLOSURE.
DO NOT OPEN THE DOOR OF THE UNIT WHEN IT IS IN OPERATION
WITHOUT PROPER PERMISSION FROM THE AUTHORITIES.
DANGEROUSLY HIGH VOLTAGES APPEAR WITHIN THE EQUIPMENT.
EXTREME CARE MUST BE TAKEN TO AVOID ELECTRIC SHOCK.