Operating instructions

7.16 Raw Water Pump with Connections
7.16.1 Raw water pump – Relief bore check
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury – danger to life!
Take special care when working on a running engine.
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
Wear ear protectors.
Raw water pump – Relief bore
check
1. Check relief bore for oil and coolant dis‐
charge.
2. Stop engine (→ Page 55) and disable en‐
gine start.
3. Clean the relief bore with a wire if it is dirty.
Permissible coolant discharge: up to 10
drops per hour;
Permissible oil discharge: up to 5 drops
per hour.
4. If discharge exceeds the specified limits,
contact Service.
122 | Task Description | M015650/04E 2012-02
TIM-ID: 0000007284 - 001