Operating instructions

Open-loop control:
Injection (fuel pressure, injection timing, injection duration, operating status)
Sequential turbocharging (cutting-in and out) with secondary turbocharger
Engine protection with multi-stage safety systems:
Power reduction
Power limitation
Emergency stop
Monitoring:
Exhaust gas temperature, A-side
Exhaust temperature, B-side
Engine speed
Oil pressure
Differential oil pressure
Coolant temperature
Coolant level
Exhaust turbocharger speed
Leak fuel level
Oil temperature
Coolant pressure
Fuel pressure after filter
Monitoring in engine room
Engine control and monitoring unit (LOP)
Functions:
Engine speed, oil pressure and coolant temperature are monitored and displayed
Integrated safety system
Integrated test system
Redundant CAN bus interface to governor and higher-level control and monitoring system
24 V DC power supply
20 | General Information | M015650/04E 2012-02
TIM-ID: 0000002177 - 002