Operating instructions

RAW WATER CIRCUIT (open circuit)
Number of cylinders 12
Raw water pump: Inlet pressure, min. L bar -0.4
Raw water pump: inlet pressure, max. L bar +0.5
Pressure loss in engine-external raw water system, max. L bar 0.7
LUBE OIL SYSTEM
Number of cylinders 12
Lube oil operating temperature upstream of engine, from R °C 82
Lube-oil operating temperature upstream of engine, to R °C 92
Lube oil operating pressure upstream of engine, from R bar 7.5
Lube oil operating pressure upstream of engine, to R bar 8.5
Lube oil operating pressure (low idle) (meas. point: upstream of engine) R bar 3
FUEL SYSTEM
Number of cylinders 12
Fuel pressure at engine inlet connection, min. (when engine is starting) L bar -0.3
Fuel pressure at engine inlet connection, min. (when engine is running), L bar -0.3
Fuel pressure at engine inlet connection, max. (when engine is starting) L bar +0.25
Fuel supply flow, max. R liters/min 7.1
GENERAL OPERATING DATA
Number of cylinders 12
Firing speed, from R rpm 100
Firing speed, to R rpm 120
STARTER (electric)
Number of cylinders 12
Rated starter voltage (standard design) R V= 24
INCLINATIONS, STANDARD OIL SYSTEM (reference: waterline)
Number of cylinders 12
Longitudinal inclination, continuous max. driving end down (Option: max.
operating inclinations)
L Degrees
(°)
15
Longitudinal inclination, temporary max. driving end down (Option: max. op‐
erating inclinations)
L Degrees
(°)
22.5
Longitudinal inclination, continuous max. driving end up (Option: max. oper‐
ating inclinations)
L Degrees
(°)
0
Longitudinal inclination, temporary max., driving end up (Option: max. oper‐
ating inclinations)
L Degrees
(°)
10
Transverse inclination, continuous max. (Option: max. operating inclina‐
tions)
L Degrees
(°)
22.5
Transverse inclination, temporary max. (Option: max. operating inclinations) L Degrees
(°)
32.5
34 | Technical Data | MS150061/03E 2012-02
TIM-ID: 0000010852 - 002