Review is only for general conformance with the design concept of the project and general compliance with the information given in the contract documents. Any action shown is subject to the requirements of the plans and specifications. Contractor is responsible for: Dimensions, which shall be confirmed and correlated at the job site; fabrication processes and techniques of construction; coordination of his work with all other trades and the satisfactory performance of his work.
Corporate - 29395 Wall St. Wixom, MI 48393 West MI - 2385 Wilshere Drive Jenison, MI 49428 800.419.5199 Fax: 248.374.
Engine Primary Filter: Engine Secondary Filter: Water Separator On Engine: Supplemental 30um filt/sep: PRODUCT MANUALS Copies of Operating Manual: WARRANTY Labor Warranty: Parts Warranty: TESTING Standard Test 1.
IDLC350-3D Ratings Range – 60 Hertz Operation Standby: kW 200 - 350 kVA 200 - 438 Prime: kW 185 - 320 kVA 185 - 400 Diesel Standby and Prime Power Features 4 Heavy-duty industrial diesel engine that meets the latest EPA emissions levels 4 Brushless synchronous alternators with dynamic balancing and four pole construction 4 Fully featured microprocessor based controller that’s easy to use and field programmable for customized installations Baldor generators are available in a variety of power
Engine Application Data Engine Specifications Manufacturer Engine Model # Engine Type Induction System Displacement, L (in3) EPA Emissions Level HP at Rated Speed BHP (kWm) Rated RPM Bore and Stroke in(mm) Compression Ratio Air Filter Type Governor Type/Model Governor Manufacturer Freq Reg NL to FL Freq Reg Steady State Engine Lubrication System Oil Pan Capacity gal(L) Oil Pan w/Filter Oil Filter Quantity Oil Filter Type Oil Cooler Recommended Oil Oil Press psi(kPa) Engine Cooling System Genset Max Ambient
Alternator Specifications Alternator Type Exciter Type Excitation System Insulation Material Standby Temp Rise Prime Temp Rise Lead Connection Stator Pitch Amortisseur Winding Bearing Drive Coupling Unbalanced Load 4-Pole, Rotating Field Automatic Voltage Regulator Brushless PMG Std MX341, Opt MX321 PMG Voltage Regulation No Load to Full Load per NEMA MG1 PMG Regulator +/- 1%, +/- 0.
Additional Standard Genset Features Available Accessories and Options 4 Formed Steel Sub-Base Open Unit q Industrial Silencer q Residential Silencer q Critical Silencer q Super Critical Silencer q Exhaust Flex Pipe q Rain Cap q Radiator Duct Flange Enclosed Units q Weather Resistant Enclosure q Sound Attenuated w/Internal Critical Silencer q ISO Container q Walk-In Enclosure Alternator Accessories q PMG Exciter and AVR Upgrade q Alternator Space Heater q Exciter Field Circuit Breaker q Alternator Drip Sh
COMPLY WITH APPLICABLE STATE AND LOCAL GOVERNMENT NOISE LEVEL 2 PER 63213D,1.5,I Enclosure Packages Sound Attenuated HPE Level One Specification Available Upon Request Sound Attenuated HPE Level Two Specification Available Upon Request Sound Attenuated HPE Level Three Specification Available Upon Request Applicable to all models above 250 kW Applicable to all models above 900 kW Applicable to all models above 500 kW Applicable to all models • 14 gauge steel ASTM A569, #4 finish • Optional 0.
Paint Specification - applicable to all Enclosures (Detailed paint specification follows on page 2 of Appendix F) Powder Paint System consisting of the following: Almond is our standard color. Please notify PMT before final approval 1. Three stage wash system with Phosphate treatment 2. Application of sealant 3. Electrostatically applied enamel based powder paint 1.5 to 2.5 mil thickness 4. Baked at 400o for 15 mintues 5. Almond is our standard color COORDINATE FINAL COLOR WITH OWNER PER 263213D,2.
This is the certification information for the Detroit Diesel Engine. The certificate meets EPA guidelines based on manufactured date of engine. We will be utilizing the 2011 engine indicated above.
5 4 4 -% ?$+ % A # -%-'3E'& &&% G $)%% " ! $% (& &% ,& $%% ! $% (& &% ,& $%% && $') (,& +$' &&% " # % &'( % '*+ % ',% % '-( % '+' && $') (,& +$' &&% " # % &'( % '*+ % ',% % '-( % '+' ! $% (& &% ,& $%% $$% %-F%+=)$+& ! $% (& &% ,& $%% +) $$* ('* '&) +,, &(&
5 4 4 -% ?$+ % A # -%-'3E'& &&% G $)%% " 4 -% 3H # ',%
5 4 4 -% ?$+ % A # -%-'3E'& &&% G $)%% " . %-F%+=)$+& 4 -% 3H # ',%
5 4 4 -% ?$+ % A ) ' 0 -%-'3E'& &&% G $)%% " 5 ) = 8 : = ; 9 . : = ; : I ?:; = I 0 ?8 I # 8 A = I 0 ? 8 A = ; I 4 3 = ; :; 8 : = : 8 = = ; .
5 4 4 -% ?$+ % A # -%-'3E'& &&% G $)%% " 7 + ! 1 ? I A @4 F ?. $A @4 F ?. (A @4 F ?. 'A @4 F ?. +A :@89 F ?4 0A :@89 F ?4 00A :@89 F ?4 000A :@89 F ?4 0EA 4 N = ?4 N= A F F F F F F F &&'+ &) + O F .
5 4 4 -% ?$+ % A # -%-'3E'& &&% G $)%% " F 4 %-F%+=)$+& <= > + ' )9 <= > + / : 9 <= > # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # . .
5 4 4 -% ?$+ % A 4 7 = -%-'3E'& 4 7 @ 5 F . = 4 # O %-Q%$2-%** 5 # 0 2 < ?4 : $&$'A 5 0 J R :; C . 0 < C 5 4 # 4 7 < ' . = = : 6=: 7 = O 6=O 7 J 6 7 . ?4 . # < H A $ +)- ( &&* ' )% K + ' 0 .
5 4 4 -% ?$+ % A !34 ; ): . = # 3 = # 4 9 = . N 6 7 N 6 7 F < # # 9 < 8 ( $ !34 ; ): 6 . = 8 F < # # 5='&&% 6 ; ): . = # 3 = # 4 9 = .
5 4 4 -% ?$+ % A # -%-'3E'& : 4 1 + & = F F 2 4 < # # 4 4 : 4 : . E 4 . -%-'3E'& & (+ - -$ $+( > )&& > F .
HCI 434F/444F - Technical Data Sheet
HCI434F/444F SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. VOLTAGE REGULATORS SX440 AVR - STANDARD With this self-excited system the main stator provides power via the Automatic Voltage Regulator (AVR) to the exciter stator.
HCI434F/444F WINDING 311 CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G. A.V.R. MX321 MX341 VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) CONTROL SYSTEM SELF EXCITED A.V.R. SX440 SX421 VOLTAGE REGULATION ± 1.0 % ± 0.5 % SUSTAINED SHORT CIRCUIT With 4% ENGINE GOVERNING WILL NOT SUSTAIN A SHORT CIRCUIT INSULATION SYSTEM CLASS H IP23 PROTECTION 0.
HCI434F/444F Winding 311 THREE PHASE EFFICIENCY CURVES 60 Hz 5
HCI434F/444F Winding 311 Locked Rotor Motor Starting Curve 50 Hz MX 346V 30 380V 400V 415V SX 440V 380V 400V 415V 440V 25 P E R C E N T T R A N S IE N T V O L T A G E D I P . 25 P E R C E N T T R A N S IE N T V O L T A G E D IP .
HCI434F/444F Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection. 50 Hz 10000 SYMMETRICAL CURRENT (Amps) ASYMMETRICAL 1000 100 0.001 0.01 0.1 TIME (secs) 1 10 Sustained Short Circuit = 1,750 Amps 60 Hz CURRENT (Amps) 10000 1000 SYMMETRICAL ASYMMETRICAL 100 0.001 0.01 0.1 TIME (secs) 1 10 Sustained Short Circuit = 2,000 Amps Note 1 The following multiplication factors should be used to adjust the values from curve between time 0.
PROVIDE TEMPERATURE RISE OF 105 DEGREE C STAND-BY RATING PER SPECIFICATION SECTION 26 3213D, 2.9, D. Continuous Duty is rated for an extended outage and Standby is rated for a day or two outage. So the Continuous duty is a better rating. Hz 60 Hz Winding 311 / 0.8 Power Factor RATINGS Cont. F - 105/40°C Class - Temp Rise 50 HCI434F/444F Cont.
Industrial Tank Heaters Ambient Above -20° F Ambient Below -20° F (Conduit Connection) 350 — 500 Cubic Inch or Less 200 — 300 Cubic Inch or Less 1500 - 5000 watt Weathertight Single Phase 500 — 600 Cubic Inch or Less 300 — 400 Cubic Inch or Less 600 — 800 Cubic Inch or Less 400 — 500 Cubic Inch or Less 800 — 1000 Cubic Inch or Less 500 — 600 Cubic Inch or Less 1000 — 1350 Cubic Inch or Less 600 — 800 Cubic Inch or Less CB Model without thermostat. CB Model assembled with thermostat.
Model Number Volts Watts CB115100-000 CB115800-000 CB115200-000 CB115700-000 CB115300-000 CB115400-000 120 208 240 277 380 480 CB120100-000 CB120800-000 CB120200-000 CB120300-000 CB120400-000 Replaceable Parts Element Mounting Check Box O-ring Kit Valve RTBCB TMM-OR FK2 RV-M RTBCB TMM-OR FK2 RV-M RTBCB TMM-OR FK2 RV-M RTBCB TMM-OR FK2 RV-M RTBCB TMM-OR FK2 RV-M RTBCB TMM-OR FK2 RV-M Element Tank 1500 1500 1500 1500 1500 1500 RECB1151 RECB1158 RECB1152 RECB1157 RECB1153 RECB1154 RTB RTB RTB RTB RT
The right choice for hauling, harvesting, plowing and lifting Too bad all choices can’t be this easy. EXIDE Heavy Duty Batteries. Start Positive. Stay Positive. EXIDE HEAVY DUTY COMMERCIAL SERIES BATTERIES A HEAVY DUTY BATTERY FOR EVERY HEAVY DUTY JOB. From farm to factory and everywhere in between, there’s an Exide Heavy Duty Battery with the power to get the job done.
EXIDE ® HEAVY DUTY SPECIFICATIONS BCI GROUP SIZE PART NUMBER CCA @ 0º F CCA @ 32º F** RC MIN @25A EXIDE® HEAVY DUTY Commercial Series & Farm Batteries — 12 VOLT 3EE F-3EE 370 440 100 3ET F-3ET 460 550 120 4D COM-4D-P 1000 1200 320 4DLT F-4DLT 820 970 250 1300 1560 435 COM-8D COM-8D (312) 1300 1560 435 COM-8D (313) 1300 1560 435 COM-8D (314) 1300 1560 435 COM-8D (316) 1300 1560 435 8D* COM-8D-P 1155 1380 400 COM-8D-P (312) 1155 1380 400 COM-8D-P (313) 1155 1380 400 COM-8D-P (314) 1155 1380 400 COM-8D-P
NRG Intelligent Engine Start Battery Charger The Smart Choice for Mission-Critical Engine Starting • • • • • Fast, accurate, mission-critical charging – gives best starting reliability Replace nearly any charger – without planning ahead Industry-first battery-fault alarm - helps dispatch service early 1 million hour observed MTBF – means longest charger life Smart design – stops load dump and other damaging transients www.sens-usa.com • info@sens-usa.com • Toll-free 866.736.7872 • 303.678.
NRG Battery Charger Benefits and Features Failure to start due to battery problems is the leading cause of inoperable engine generator sets. SENS NRG battery charger maximizes starting system reliability while slashing genset servicing costs: One NRG replaces almost any charger without extra site visits. Installers can select or change at any time 120, 208 or 240 volts AC input, 12 or 24-volt battery and output settings optimized for nearly any lead-acid or nickel cadmium battery.
NRG Specifications AC Input Voltage Input current 110-120/208-240 VAC, +10%, single phase, switch selectable 10A charger: 6.6/3.3 amps maximum 20A charger: 12.6/6.3 amps maximum 60 Hz +5% standard; 50/60 Hz +5% optional 1-pole fuse, soft-start, transient suppression Frequency Input protection Charger Output Nominal voltage ratings Optional voltage rating Battery settings 12 or 24 volt nominal 12/24 volt, field selectable Six discrete battery voltage programs - Low or high S.G. flooded - Low or high S.
Controls AC input voltage select Optional 12/24-volt output select Battery program select Fast charger enable/disable Temp compensation enable Remote temp comp enable Environmental Operating temperature Over temperature protection Humidity Vibration (10A unit) Transient immunity Agency Standards Safety Agency marking EMI NFPA standards Optional agency compliance Construction Housing/configuration Packaging Dimensions Printed circuit card Cooling Protection degree Damage prevention Electrical connect
Drawings and Dimensions 10A Chargers 10A Chargers Enclosed and Open Frame Configurations Slimline Open Frame Configuration ����� ���� ��� ����� ������ � ���� ���� Slimline can be mounted either flat or edgewise ��� ���� ����� ���� Open-frame configuration omits front cover 20A Chargers Enclosed and Open Frame Configurations ����� ����� ������ ����� ����� ���� Open-frame configuration omits front cover ������� ���������� ����� ���� ������������� �� �������� �� ���������� �� �������� � ���� ��
111009 B ��� �������� ����������� ������ ����� �� �� �� �� ����� ����� �� �� ����� ������ ���� �� �� �� �� �� �� �� �� �� ����� ��������� �������������� ����������� ����������� ����������� ����������� ����������� ����������� ����������� ����������� ����������� ��������� ����������� �������� ��������� �������� ��������� ����������� �������� ��������� �������� ��������� ����������� �������� ��������� �������� ��������� ���������� ��������� ���������� ��������� ���������� ���� ��� ������ �� ��� �� ��� �
InteliGen NT GENERAL PURPOSE HIGH-END GEN-SET CONTROLLER Description InteliGenNT is a comprehensive controller for both single and multiple gen-sets operating in standby or parallel modes. Compact construction is optimized for these purposes and various HW modifications allow customers to select the optimum type for a particular application. A built-in synchronizer and digital isochronous load sharer allow a total integrated solution for gen-sets in standby, island parallel or mains parallel.
Features Integrated fixed and configurable protections InteliGenNT Support of engines with ECU (J1939, Modbus and other proprietary interfaces); alarm codes displayed in text form AMF function Automatic synchronizing and power control (via speed governor or ECU) Baseload, Import / Export Peak shaving Voltage and PF control (AVR) Generator measurement: U, I, Hz, kW, kVAr, kVA, PF, kWh, kVAhr Mains measurement: U, I, Hz, kW, kVAr, PF Inputs and outputs configurable for various cus
Communication modules and PC tools Upgrade kits I-CR – CAN repeater module IG-IB – Internet bridge I-LB+ – Local bridge I-CB – ECU communication bridge InteliMonitor – PC monitoring tool InteliSupervisor – PC tool for Gen-set or machines fleet management WinScope – Special graphical controllers‘ monitoring software GenConfig – PC configuration tool IGS-NT-LSM+PMS dongle: • Enables Multiple isolated parallel or multiple parallel with mains • Power management operation (with CAN
InteliGenNT RELATED PRODUCTS InteliGenNT Marine HIGH-END MARINE CERTIFIED GEN-SET CONTROLLER InteliGenNT Marine is a comprehensive controller for both single and multiple gen-sets operating in standby or parallel modes for marine applications. IS-NT-BB InteliSysNT or PREMIUM AND COGENERATION GEN–SET CONTROLLER InteliSysNT is an expandable controller for both single and multiple gen-sets operating in standby or parallel modes, especially in cogeneration (CHP) and other complex applications.
InteliVision CREATIVE ENGINEERING CONTROLLER DISPLAY UNIT Description InteliVision is a new generation display unit for either InteliGenNT / InteliSysNT or InteliDrive controllers. It is designed as a simple, easy to use Plug and Play solution and has been developed from our original IS-Display. The new InteliVision screen features many significant improvements such as the large high-resolution colour TFT display, which helps visibility and definition for onscreen information.
InteliVision with InteliDrive controllers (all possible connections) Features RS 232 CAN VISION INTELI ID-DCU VISION INTELI VISION INTELI CAN ID-DCU InteliVision with IGS-NT controllers (all possible connections) VISION INTELI 2 CAN * (1) /RS232 RS485 2 2 3 4 INTELI * (2) /RS232 RS485 2 2 3 1 CAN VISION INTELI IGS-NT 2 N 4 INTELIVISIO IGS-NT VISION 2 3 3 N LIVISIO INTE one rt only 32 po *via RS2 IS-NT-BB 1 it can be ion un InteliVis / IG-NTC IS-NT-BB 2 IG
Modules Kit 1: iGL-RA15, Remote Annuciation Module When NFPA110 approval is required the RA15 can be added for remote annunciation. Pictures and features of the RA15 can be seen below. Kit 1: iGL-RA15, Remote Annunciation Module • 15 three-color LEDS • CAN Bus connection to unit • User definable labeling • 1 connection for siren • LED color is determined using the front • Horn reset and lamp test keys panel buttons(R/G/Y) • Max.
Oiltight Switches & Pilot Devices ø22mm - HW Series Display Lights Switches & Pilot Lights Non-illuminated E-Stop Pushbuttons (Assembled) Ø40mm Head Pushlock Turn Reset Contacts Plastic Bezel Metal Bezel Plastic Bezel Metal Bezel Operator Only HW1B-V3M† HW4B-V3M† HW1B-V4M† HW4B-V4M† 1NO HW1B-V3F10-M† HW4B-V3F10-M† HW1B-V4F10-M† HW4B-V4F10-M† 1NC HW1B-V3F01-M† HW4B-V3F01-M† HW1B-V4F01-M† HW4B-V4F01-M† 1NO-1NC HW1B-V3F11-M† HW4B-V3F11-M† HW1B-V4F11-M† HW4B-V4F11-M† 2NO HW1B-V3F
Oiltight Switches & Pilot Devices ø22mm - HW Series Part Number Structure W 1 B – V 3 F 10 – R – EMO-2 Engraved Button* Bezel EMO-2: EMO switch 1: Plastic Bezel 4: Metal Bezel Function V: Pushlock Turn Reset X: Pushlock Key Reset (not available for 60mm jumbo mushroom) *Option available for red EMO E-Stop only Operator 3: ø29mm Head 4: ø40mm Head 5: ø60mm Head Button Colors Contact Arrangement Terminals F: Fingersafe C: Exposed Screw blank: Springup 10: 1NO 01: 1NC 11: 1NO-NC R: Red Y: Y
PowerpactMhandout 2/2/05 8:55 AM Page 1 Powerpact® M-Frame Molded Case Circuit Breakers Offering improved performance and efficiency Powerpact M-Frame Molded Case Circuit Breakers provide improved performance and a compact solution for up to 800A applications. They complement the existing Powerpact P- and R-Frame, and replace the traditional MA/MH Circuit Breakers with smaller footprint and competitive cost.
PowerpactMhandout 2/2/05 8:55 AM Page 2 Powerpact® M-Frame Molded Case Circuit Breakers Features Comparison Features Amp Rating 2P and 3P Interrupting Rating (kA) (240/480/600 V) Powerpact M-Frame Circuit Breaker Accessories Square D® MA/MH Square D Powerpact M Square D Powerpact P 300A – 1200A 300A – 800A 250A – 1200A Yes Yes Yes MA: 42/30/22 MH: 65/65/25 G: 65/35/18 J: 100/65/25 G: 65/35/18 J: 100/65/25 K: 65/50/50 L: 125/100/- Shunt Trip (various AC and DC voltages are available)
Engine Silencers Silencers - Compact RFB Series 2 5 - 3 0 d BA Critical Grade Application & Performance Call Silex for immediate assistance in selecting the appropriate silencer that best suits your application’s acoustical and backpressure requirements or consult the silencer selection guide in our catalogue. You can also use Silex’s exclusive Silencer Sizing and Selection Program “Silex Digital Engineer” found on the Company’s secure website at www.silex.com.
Corporate - 29395 Wall St. Wixom, MI 48393 West MI - 2385 Wilshere Drive Jenison, MI 49428 800.419.5199 Fax: 248.374.
Standard 3 Year Standby Generator Set Comprehensive Warranty Baldor’s warranty applies to all prod ucts manufactured by Baldor which are for use in the United States. Baldor warrants that the p roduct is to be free from defects in materials and workmanship to the original purchaser, for five (3) years or 1000 hours from date of delivery or start up.