Technical data

Troubleshooting 5–11
Fault code Alarm text Meaning Task
250 SD CAN SPEED
DEMAND
Sensor defect (CAN nominal
speed demand)
1. Check speed transmitter.
2. Check wiring (CAN bus).
3. Contact Service.
266 SD SPEED
DEMAND AN.
Sensor defect (analog nominal
speed demand)
1. Check speed transmitter.
2. Check wiring.
3. Contact Service.
267 SD
SP.DEM.TEST
BENCH
Sensor defect (analog speed
demand);
NOTE:
Only used in test-stand
operation.
1. Check speed transmitter.
2. Check wiring.
3. Contact Service.
270 SD SPEED
DEMAND FI1
Sensor defect (frequency
input for speed demand);
1. Check speed transmitter.
2. Check wiring.
3. Contact Service.
271 SD T-EXTERN 1 External device defective
(CAN T-EXTERN 1)
Contact Service.
272 SD T-EXTERN 2 External device defective
(CAN T-EXTERN 2)
Contact Service.
273 SD P-EXTERN 1 External device defective
(CAN P-EXTERN 1)
Contact Service.
274 SD P-EXTERN 2 External device defective
(CAN P-EXTERN 2)
Contact Service.
275 SD
EXT.COOLANT
LEVEL
External coolant-level
monitoring defective (CAN)
Contact Service.
276 SD
INTERCOOLER
LEVEL
External charge-air
coolant-level monitoring
defective (CAN)
Contact Service.
277 SD BIN-EXTERN
3
External device defective
(CAN BIN-EXTERN 3)
Contact Service.
278 SD BIN-EXTERN
4
External device defective
(CAN BIN-EXTERN 4)
Contact Service.
301 TIMING
CYLINDER A1
Injection timing fault cylinder
A1
If fault occurs repeatedly: Contact Service.
302 TIMING
CYLINDER A2
Injection timing fault cylinder
A2
If fault occurs repeatedly: Contact Service.
303 TIMING
CYLINDER A3
Injection timing fault cylinder
A3
If fault occurs repeatedly: Contact Service.
304 TIMING
CYLINDER A4
Injection timing fault cylinder
A4
If fault occurs repeatedly: Contact Service.
305 TIMING
CYLINDER A5
Injection timing fault cylinder
A5
If fault occurs repeatedly: Contact Service.
306 TIMING
CYLINDER A6
Injection timing fault cylinder
A6
If fault occurs repeatedly: Contact Service.
M015560/00E 03-05 ©MTU