Technical data
Injection Pump / H P Pump 6–15
6.5.2 Injection pump removal and installation
Preconditions
• Engine is stopped and starting disabled.
Special tools
Designation / Use Part No. Qty.
Barring t ool
Material
Designation / Use Part No. Qty.
Petroleum jelly
Spare parts
Designation / Use Part No. Qty.
Sealing ring
Sealing ring
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury — danger to life!
• Before barring the engine, ensure that nobody is in the danger zone.
WARNING
Fuels are combustible.
Risk of fire and explosion!
• Avoid naked flames, electrical sparks and ignition sources.
• Do not smoke.
Preparatory steps
1. Shut off fuel supply line before fuel filter.
2. Remove engine control system (→ Page 6 – 63).
3. Drain fuel (→ Page 6 – 22).
4. Remove charge-air manifold and all seals.
M015560/00E 03-05 ©MTU