Technical data

Injection Pump / H P Pump 6–15
6.5.2 Injection pump removal and installation
Preconditions
Engine is stopped and starting disabled.
Special tools
Designation / Use Part No. Qty.
Barring t ool
Material
Designation / Use Part No. Qty.
Petroleum jelly
Spare parts
Designation / Use Part No. Qty.
Sealing ring
Sealing ring
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury danger to life!
Before barring the engine, ensure that nobody is in the danger zone.
WARNING
Fuels are combustible.
Risk of fire and explosion!
Avoid naked flames, electrical sparks and ignition sources.
Do not smoke.
Preparatory steps
1. Shut off fuel supply line before fuel filter.
2. Remove engine control system ( Page 6 63).
3. Drain fuel ( Page 6 22).
4. Remove charge-air manifold and all seals.
M015560/00E 03-05 ©MTU