Technical data

6–48 Cooling System, LT Circuit
6.16 Cooling System, LT Circuit
6.16.1 Charge-air coolant filling
Preconditions
Engine is stopped and starting disabled.
MTU Fluids and Lubricants Specification (A001061/..) is available.
Material
Designation / Use Part No. Qty.
Coolant
Spare parts
Designation / Use Part No. Qty.
Sealing ring
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
Wear ear protectors.
CAUTION
Cold coolant in hot engine can cause thermal stress.
Formation of cracks in components!
Fill / top up coolant only into cold engine.
Preparatory steps
1. Turn breather valve on coolant expansion tank
counterclockwise to first stop and allow pressure
to escape.
2. Continue to turn breather valve counterclockwise
and remove.
3
.
R
emove plug screw from filling point on coolant
line to intercooler.
Charge-air coolant filling
1. Fill treated coolant through filling line or through filler neck of coolant expansion t ank until coolant level
reaches marking plate.
2. Install plug screws of filling points with new sealing rings.
3. Check proper condition of breather valve and clean sealing faces, if required.
4. Set breather valve onto filler neck and close it.
M015560/00E 03-05 ©MTU